Introduction; General; Hazardous Information Messages; Safety Information - Daikin Maverick I Installation And Maintenance Manual

Commercial packaged rooftop systems
Hide thumbs Also See for Maverick I:
Table of Contents

Advertisement

General

This manual contains the installation and operating instructions
for your packaged rooftop system. There are some precautions
that should be taken to derive maximum satisfaction from it.
Improper installation can result in unsatisfactory operation or
dangerous conditions. Read this manual and any instructions
packaged with separate equipment prior to installation. Give
this manual to the owner and explain its provisions. The owner
should retain this manual for future reference.

Hazardous Information Messages

Cautions indicate potentially hazardous situations, which can result in
personal injury or equipment damage if not avoided.
Warnings indicate potentially hazardous situations, which can result in
property damage, severe personal injury, or death if not avoided.
Dangers indicate a hazardous electrical situation which will result in death
or serious injury if not avoided.
Dangers indicate a hazardous gas situation which will result in death or
serious injury if not avoided.
Notices give important information concerning a process, procedure,
special handling or equipment attributes.
www.DaikinApplied.com
CAUTION
WARNING
DANGER
DANGER
NOTICE

Safety Information

The manufacturer's warranty does not cover any damage or defect to
the air conditioner caused by the attachment or use of any components,
accessories or devices (other than those authorized by the manufacturer)
into, onto, or in conjunction with the air conditioner. you should be aware
that the use of unauthorized components, accessories or devices may
adversely affect the operation of the air conditioner and may also endanger
life and property. The manufacturer disclaims any responsibility for such
loss or injury resulting from the use of such unauthorized components,
accessories or devices
Install this unit only in a location and position as specified in the Mechanical
Installation section of these instructions. Provide adequate combustion and
ventilation air to the unit space as specified in the venting section of these
instructions.
Provide adequate combustion and ventilation air to the unit space as
specified in the combustion and ventilation air section of these instructions.
Combustion products must be discharged outdoors. Connect this unit to an
approved vent system only, as specified in Mechanical Installation section
of these instructions.
Use only with type of gas approved for this unit. Refer to the unit rating
plate.
Never test for gas leaks with an open flame. It can cause an explosion or fire
resulting in property damage, personal injury or death. Use a commercially
available soap solution made specifically for the detection of leaks to check
all connections, as specified in the Mechanical Installation section of these
instructions.
Always install unit to operate within the unit's intended temperature-rise
range with a duct system which has an external static pressure within the
allowable range, as specified in the Mechanical Installation section of these
instructions. See also unit rating plate.
Units are not design certified to be installed inside the structure. Doing so
can cause inadequate unit performance as well as property damage and
carbon monoxide poisoning resulting in personal injury or death.
3
IM 972-2 • MAVERICK I ROOFTOP SYSTEMS

Introduction

NOTICE
WARNING
DANGER
WARNING
Introduction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mps015bMps025bMps020b

Table of Contents