Unit Capacity and Physical Data

Table 8: MPS 015B – 025B
Model
Cooling Performance
1
Gross cooling BTU [kW]
EER/SEER
2
Nominal airflow/ARI airflow (cfm) [L/s]
Net cooling BTU [kw]
Net sensible BTU [kW]
Net latent BTU [kW]
Net system power kW
Compressor(s)
Type/number
Gas Heating Performance
3
AFUE %
Steady stage efficiency %
No. stages
Gas connection size
Heating input (BtuH)
Heating output (BtuH)
Temperature rise °F
Sound
4
Outdoor rating (dB)
Outdoor Coil
Fin type
Tube type
Tube size OD (in.) [mm]
Face area (sq.ft.) [sq.m.]
Rows (fpi) [fpcm]
Indoor Coil
Fin type
Tube type
Tube size OD (in.) [mm]
Face area (sq.ft.) [sq.m.]
Rows (fpi) [fpcm]
Refrigerant control
Drain connection (in.) [mm]
Condenser Fan
Type
No. used/diameter (in.) [mm]
Drive type/No. of speeds
CFM [L/s]
Motor hp
Motor rpm
Indoor Fan
Type
No. used/diameter (in.) [mm]
No. motors
Motor hp (low static, high static)
Motor rpm
Filter
Fin type
Furnished
No. size (in.) [mm]
Refrigerant
Charge oz. [g]
Weight
Net weight lbs. [kg]
Shipping weight lbs. [kg]
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motorheat. AHRI capacity is net and includes
the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified inaccordance with the Unitary Air Conditioner Equipment certification program, which is
based on AHRI Standard 210/240 or 360.
2. EER is rated at AHRI conditions and in accordance with DOE test procedures.
3. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using ANSI standards.
4. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Outdoor Sound Rating shown
is tested in accordance with AHRI Standard 270.
IM 972-2 • MAVERICK I ROOFTOP SYSTEMS
015B
188,000 [55.08]
11.1/NA
6000/5900 [2831/2784]
182,000 [53.33]
135,700 [39.76]
46,300 [13.57]
16.35
Scroll/2
80
81
2
1/2" – 3/4"
250,000 / 350,000
203,000 / 284,000
15 – 60
91
Louvered
Rifled
0.375 [9.5]
53.3 [4.95]
1/22 [9]
Louvered
Rifled
0.375 [9.5]
26.67 [2.48]
2/18 [7]
TX valves
1" [25.4]
Propeller
4/24 [609.6]
Direct/1
16000 [7550]
4 at 1/3 HP
1075
FC Centrifugal
2/18×9 [457×229]
1
3, 5
1725
Disposable
Yes
(8) 2×25×20 [51×635×508]
205/211 [5812/5982]
2000 [907]
2100 [953]
22
MPS
020B
244,000 [71.49]
11.1/NA
8000/7725 [3775/3645]
234,000 [68.56]
171,600 [50.28]
62,400 [18.28]
21.04
Scroll/2
80
81
2
3/4"
300,000 / 400,000
243,000 / 324,000
15 – 55
91
Louvered
Rifled
0.375 [9.5]
53.3 [4.95]
2/22 [9]
Louvered
Rifled
0.375 [9.5]
26.67 [2.48]
3/13 [5]
TX valves
1" [25.4]
Propeller
6/24 [609.6]
Direct/1
19800 [9344]
6 at 1/3 HP
1075
FC Centrifugal
2/18×9 [457×229]
1
5, 7-1/2
1725
Disposable
Yes
(8) 2×25×20 [51×635×508]
402/331 [11397/9384]
2341 [1062]
2441 [1107]

Physical Data

Physical Data
025B
312,000 [91.42]
10/NA
10000/9475 [4719/4471]
294,000 [86.14]
214,100 [62.73]
79,900 [23.41]
29.39
Scroll/2
80
81
2
3/4"
300,000 / 400,000
243,000 / 324,000
10 – 45
92
Louvered
Rifled
0.375 [9.5]
53.3 [4.95]
2/22 [9]
Louvered
Rifled
0.375 [9.5]
26.67 [2.48]
4/15 [6]
TX valves
1" [25.4]
Propeller
6/24 [609.6]
Direct/1
19800 [9344]
6 at 1/3 HP
1075
FC Centrifugal
2/18×9 [457×229]
1
7-1/2, 10
1725
Disposable
Yes
(8) 2×25×20 [51×635×508]
339/357 [9611/10121]
2433 [1104]
2533 [1149]
www.DaikinApplied.com