Impeller; Disassembling The Impeller - Johnson Pump SPX Flow CombiLineBloc Instruction Manual

In-line circulation pump in block execution
Table of Contents

Advertisement

CombiLineBloc
7.4
7.4.1
CLB/EN (1901) 6.6

Impeller

Disassembling the impeller

Figure 8:
Disassembling the impeller.
The item numbers used are referring to figure 8.
1 Remove the Back-Pull-Out unit, see paragraph 7.3.1 "Disassembling the Back-Pull-
Out unit".
2 Block the impeller (0120) against rotating, see figure 9.
Figure 9:
Loosening the impeller nut.
3 Remove the cap nut (1820). Sometimes the nut has to be heated to break the
Loctite-contact.
4 Remove the impeller (0120) with a pulley puller, or wrest the impeller by inserting for
instance 2 big screwdrivers between the impeller and the pump cover (0110).
5 Remove the impeller key (1860).
6 Remove the distance sleeve (1100) with the rotating part of the mechanical seal
(1220).
7 Pump size 200-160 only: Loosen the set screws (1260). Remove the shaft sleeve
(1200) and the rotating part of the mechanical seal (1220).