Johnson Pump Aqua Jet WPS 2.9 Instruction Manual

Johnson Pump Aqua Jet WPS 2.9 Instruction Manual

Water pressure systems

Advertisement

I N S T R U CT I O N M A N UA L
S E / E N / D E / F R / E S / I T
Aqua Jet Water Pressure Systems (WPS)
W P S 2 . 9 , 3 . 5 , 4 . 0 & 5 . 2 , 12 V / 2 4 V D C
O R I G I N A L I N S T R U CT I O N S / T R A N S L AT I O N O F O R I G I N A L I N S T R U CT I O N S
I B - 2 15 R 0 6 ( 10 / 2 017 )
R E A D A N D U N D E R S TA N D T H I S M A N UA L P R I O R TO O P E R AT I N G O R S E R V I C I N G T H I S
P R O D U CT

Advertisement

Table of Contents
loading

Summary of Contents for Johnson Pump Aqua Jet WPS 2.9

  • Page 1 I N S T R U CT I O N M A N UA L S E / E N / D E / F R / E S / I T Aqua Jet Water Pressure Systems (WPS) W P S 2 . 9 , 3 . 5 , 4 . 0 & 5 . 2 , 12 V / 2 4 V D C O R I G I N A L I N S T R U CT I O N S / T R A N S L AT I O N O F O R I G I N A L I N S T R U CT I O N S I B - 2 15 R 0 6 ( 10 / 2 017 ) R E A D A N D U N D E R S TA N D T H I S M A N UA L P R I O R TO O P E R AT I N G O R S E R V I C I N G T H I S...
  • Page 2: Type Designation

    > English Aqua Jet WPS Water Pressure Systems mounted to DC motor 12/24 V Typical applications pump is made at the factory. Warranty The WPS pump is a five chamber posi- invalidated by pressure switch interfe- tive displacement diaphragm pump. rence.
  • Page 3: Installation And Maintenance

    > English Pressure and capacity data Installation and maintenance (based on water at +20°C/68°F and at full voltage of the motor) Installation Locate the pump in a dry location. WPS 2.9 If the pump is mounted vertically, the Pressure Flow Amp.
  • Page 4: Maintenance

    > English The wire connections must be sealed Wiring dimensions with a marine sealant. (based on 3% voltage drop) Note: Before installation with electrical WPS 2.9 control systems, check that equipment to be used is of sufficient rated capacity Wire size Max wire to accept amperage draw of motor.
  • Page 5 > English Start-up procedure Never start a frozen pump. Even if it is After pump installation, the system drained it might contain a small amount can be started by using the following of frozen water that locks the rotor. procedure: Service instructions •...
  • Page 6: Troubleshooting Chart

    > English Trouble-shooting chart Symptom Remedy Cause 1. Pump does not run. 1.1.1 Check fuse. If motor is overheated let 1.1 Tripped thermal protector or blown it cool down prior to restart. fuse. 1.1.2 Check battery/power supply, main 1.2 Faulty wire connection or power switch and wiring.
  • Page 7 Pos. A (18-29)
  • Page 8 WPS 2.9...
  • Page 9 Pos. A (18-29)
  • Page 10 WPS 3.5...
  • Page 11 Pos. A (19-31)
  • Page 12: Waste Handling & Material Recycling

    WPS 4.0 & 5.2 Waste handling & material recycling At the products end of life, please dispose of the product according to appli- cable law. Where applicable, please disassemble the product and recycle the parts material.