Johnson Pump AQUA JET WPS 3.4 Instruction Manual

Johnson Pump AQUA JET WPS 3.4 Instruction Manual

Water pressure systems. 12/24 v dc, 12/24 v dc

Advertisement

Instruction Manual
AQUA JET
Water Pressure Systems
WPS 3.4 12/24 V DC
WPS 5.0 12/24 V DC
IB-204/05 (0606)


Advertisement

Table of Contents
loading

Summary of Contents for Johnson Pump AQUA JET WPS 3.4

  • Page 1 Instruction Manual AQUA JET Water Pressure Systems WPS 3.4 12/24 V DC WPS 5.0 12/24 V DC IB-204/05 (0606)
  • Page 2: Working Principle

    enGLISH Water Pressure Systems 3.4 and 5.0 mounted to dc motor 12/24 V Typical applications Technical description The WPS 3.4 and the WPS 5.0 are both five Body: Nylon/Polypropylene chamber positive displacement diaphragm Valve housing: Polypropylene pumps. Valves: Santoprene/EPDM These pumps are the ideal choice for Diaphragm: Santoprene pressurizing water in a closed system such...
  • Page 3: Electrical Installation

    enGLISH Pressure and capacity data Use stainless steel hose clamps to secure tubing to quick disconnect fittings and other (based on water at +0°C/68°F and hose barbs in the system. at full voltage of the motor) A strainer must be installed in line be- WPS 3.4 fore the pump intake, to prevent debris from entering pump and inter-fering with proper...
  • Page 4: Dry Running

    enGLISH 5. Refill tank with potable water. Start-up procedure 6. Open all faucets and run until After pump installation, the system can be bleach has been purged. started by using the following procedure: Wiring table • Fill water tank • Open one tap Max 0.2 •...
  • Page 5 enGLISH 6. Mount the complete pumphead kit 5. Run pump briefly to confirm that onto the motor coupling flange water has been expelled. taking notice to fit the slot in cam (5) 6. Taps shall remain open and pump in right position against motor shaft fittings shall remain disconnected and the three slots on motor end until temperatures are above...
  • Page 6: Troubleshooting Chart

    enGLISH Trouble-shooting chart Symptom Remedy Cause 1. Pump does not run. .. Check fuse. If motor is overheated let . Tripped thermal protector or blown it cool down prior to restart. fuse. .. Check battery/power supply, main . Faulty wire connection or power switch and wiring.
  • Page 7 dimensions et poids dimensioner och vikter dimensiones y pesos dimensions and weights dimensioni e peso Abmessungen und Gewichte 67/2.638 63.5/2.5 239/9.409 209/8.228 123/4.842 Vikt 2 kg 108/4.252 Weight 2 kg / 2.20 lbs Gewicht 2 kg Poids 2 kg Peso 2 kg Dim.
  • Page 8 Reservdelslista Liste des pièces Parts list Lista de piezas Teilliste elenco delle parti...
  • Page 9 Pos A (19-31)
  • Page 10 Pos B (4-9) Pos C (4-18 except 15 )
  • Page 11 Tillbehör Accessoires Accessories Accesorios Zubehör Accessori PUMProtector Universal Strainer PUMProtector Inlet Strainer Part. no Mesh KlickTite connector Part. no Mesh KlickTite connector 09-465-0 x /” barb / 3/8” BSP 09-4653-0 Built-in KlickTite x 3/4” barb / /” BSP x /” barb / 3/8” BSP 09-465-0 x /”...