Application Area; Re-Use; Scrapping - Johnson Pump SPX Flow CombiLineBloc Instruction Manual

In-line circulation pump in block execution
Table of Contents

Advertisement

CombiLineBloc
2.8
2.9
2.10
CLB/EN (1901) 6.6
9 The operation of this water pump with variable duty points may be more efficient and
economic when controlled, for example, by the use of a variable speed drive that
matches the pump duty to the system.
10 Information relevant for disassembly, recycling or disposal at end-of-life is described
in paragraph 2.9 "Re-use", paragraph 2.10 "Scrapping" and chapter 7 "Disassembly
and assembly".
11 The benchmark efficiency Fingerprint Graphs are published for:
MEI = 0,40
ESOB 1450 rpm
ESOB 2900 rpm
ESCC 1450 rpm
ESCC 2900 rpm
ESCCi 1450 rpm
ESCCi 2900 rpm
Multistage Vertical 2900 rpm
Multistage Submersible 2900 rpm
Benchmark efficiency graphs are available under http:\\www.europump.org/
efficiencycharts.

Application area

Table 6: Application area.
Maximum capacity
Maximum head
Maximum temperature
Maximum operating pressure
Maximum speed

Re-use

The pump may only be used for other applications after prior consultation with
SPXFLOW or your supplier. Since the lastly pumped medium is not always known, the
following instructions should be observed:
1 flush the pump properly.
2 make sure the flushing liquid is discharged safely (environment!)
Take adequate precautions and use the appropriate personal protection
means like rubber gloves and spectacles!

Scrapping

If it has been decided to scrap a pump, the same flushing procedure as described for
Re-use should be followed.
MEI = 0,70
ESOB 1450 rpm
ESOB 2900 rpm
ESCC 1450 rpm
ESCC 2900 rpm
ESCCi 1450 rpm
ESCCi 2900 rpm
Multistage Vertical 2900 rpm
Multistage Submersible 2900 rpm
3
450 m
/h
100 m
120 °C (peak values of 140 °C)
6 bar (ND6)/10 bar (ND10)
-1
50 Hz: 3000 min
/ 1500 min
-1
60 Hz: 3600 min
/ 1800 min
General
-1
-1
23

Advertisement