Regularly check the personal protection systems (laser scanner) for
contamination. The cleaning intervals depend on the degree of ambient
contamination. Adapt these iteratively to your circumstances.
The safety devices of the ActiveShuttle must be checked at regular intervals for
their functionality.
The following tests must be carried out at least every 6 months.
Depending on the actual operating conditions of the vehicle, it may be necessary
to reduce the test cycle.
In addition, it may be necessary to carry out a reduced daily inspection of the
safety devices.
10.2.1

Periodic inspection - minimum requirements

The tests must be carried out by competent persons or by specially authorized and
commissioned persons and documented in a comprehensible manner.
Table 12: Periodic inspections - minimum requirements
Safety device
Emergency-stop devices
Personal protection system
(laser scanner) front and rear
Personal protection system
(laser scanner) front and rear
Personal protection system
(laser scanner) front and rear
Holding brake
If an inspection reveals an error, the ActiveShuttle must be shut down immediately.
In this case, have the vehicle and its safety devices checked by
the Bosch Rexroth Service.
3 842 560 593/2020-07 ActiveShuttle: ActiveShuttle 1.0, Bosch Rexroth AG
Maintenance and repair
NOTICE
Inspection
Checking the basic function of
the safety device.
Visual and mechanical
inspection.
Checking the basic function of
the safety device.
Checking the areas to be
protected and the detection
capability.
Check for suffi cient holding
torque.
53/68
Notes on the execution
Actuate the emergency stop
command device
- on the vehicle
- on a connected handheld
controller
and check the correct
response of the vehicle.
Check the safety device for
visible damage and correct
fastening.
See section 10.3.1. Checking
the basic function of the
personal protection systems
(laser scanner)
See section 10.3.2. Checking
the areas to be protected
Please contact Bosch Rexroth
Service for instructions on how
to perform the inspection.