  • Page 1 CANplus CP640 Control Panel Operation Manual 9M02-1000-A001-EN...
  • Page 2 Cattron Holdings, Inc., or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind. All Cattron products are sold pursuant to the Terms and Conditions of Sale, a copy of which will be furnished upon request. When used as a tradename herein, Cattron means Cattron Holdings, Inc.
  • Page 3: Table Of Contents

    CANplus CP640 - EN Control Panel Operation Manual Contents Important Safety and Emissions Information ...................... 5 Safety Notation ............................5 Safety Instructions............................ 5 Auxiliary Engine Stop Disclaimer ......................6 General Emissions Disclaimer ......................... 7 Exhaust Emissions Compliance Disclaimer ..................... 7 Overview ................................
  • Page 4 CANplus CP640 - EN Control Panel Operation Manual 6.2.1 Typical J1939 Wiring Topology ....................25 6.2.2 Engine Harness Connector ....................... 25 6.2.3 Sealed Connectors ........................26 6.2.4 Unsealed Connectors ....................... 26 6.2.5 Harness Routing ........................26 Engine Starter Excitation Connection ....................26 6.3.1 Starter Relay ..........................
  • Page 5: Important Safety And Emissions Information

    CANplus CP640 - EN Control Panel Operation Manual Important Safety and Emissions Information 1.1 Safety Notation This manual uses the following conventions to present IMPORTANT SAFETY INFORMATION to you. Please read and follow ALL SAFETY INSTRUCTIONS. WARNING IMPORTANT AND URGENT SAFETY INFORMATION – A HAZARD THAT WILL, IF NOT AVOIDED, CAUSE SERIOUS INJURY OR LOSS OF LIFE.
  • Page 6: Auxiliary Engine Stop Disclaimer

    CANplus CP640 - EN Control Panel Operation Manual CAUTION CANPLUS PRODUCTS ARE NOT DESIGNED FOR, OR INTENDED FOR USE ON, APPLICATIONS REQUIRING EXPLOSIVE PROOF COMPONENTS. FURTHER, CANPLUS PRODUCTS ARE NOT DESIGNED FOR, OR INTENDED FOR APPLICATION WITHIN, HAZARDOUS OR EXPLOSIVE ENVIRONMENTS. CAUTION THE INSTALLER OF THIS CANPLUS PRODUCT IS SOLELY RESPONSIBLE FOR ENSURING...
  • Page 7: General Emissions Disclaimer

    CANplus CP640 - EN Control Panel Operation Manual 1.4 General Emissions Disclaimer This panel may include provision(s) for operator input such as FORCE REGENERATION, INHIBIT REGENERATION, INTERLOCK and others specific to US and International emissions regulations. Responsibility for emissions-related inputs and compliance with emissions regulations is solely that of the owner and/or operator of the machine/engine on which this panel is connected.
  • Page 8: Overview

    CANplus CP640 - EN Control Panel Operation Manual Overview The CANplus CP640 control panel is an economical platform for EPA Tier 3, EPA Tier 4 (interim) and EPA Tier 4 electronically governed diesel engines. Graphical gauge pages or a single large analog gauge are displayed on the 3.5”...
  • Page 9 CANplus CP640 - EN Control Panel Operation Manual 9M02-1000-A001-EN Revision B...
  • Page 10: Display

    CANplus CP640 - EN Control Panel Operation Manual Display The CANplus display is a robust, sunlight-viewable 3.5” QVGA color display with five integrated backlit buttons housed in a rugged, water-tight IP66 rated enclosure. The five soft keys simplify and enhance the user interface by providing a configurable auditory beep and positive tactile feedback when pressed.
  • Page 11: Analog Gauge

    CANplus CP640 - EN Control Panel Operation Manual Analog Gauge Pages Analog Gauge Pages provide four independently configurable pages of analog gauges. To enable Analog Gauge Pages, press any of the first four buttons to show the top level button bar and then press button 1 to cycle through the pages, as shown below.
  • Page 12: Digital Gauge

    CANplus CP640 - EN Control Panel Operation Manual All 16 gauges may be configured to create an application-specific view of the data. With Tech or Admin level Configuration → Display → access, the four analog gauge pages can be configured using the following menu: Gauges →...
  • Page 13: Service Timers

    CANplus CP640 - EN Control Panel Operation Manual An alarm indicator is displayed near the upper right corner of the display as long as alarms are active. The indicator and alarm messages in the list are automatically removed when the alarm has not been received for a few seconds.
  • Page 14: Menu Tree

    CANplus CP640 - EN Control Panel Operation Manual The menus pages can also be accessed by pressing and holding the optional Rotary Control using RotaryPlus technology: • Push and hold the rotary for 1 second to open the menus main page Move down through the menu choices with clockwise rotations •...
  • Page 15 CANplus CP640 - EN Control Panel Operation Manual Display Language • Units • Distance Pressure Volume Temperature Button Beep – ON/OFF • Gauges • – Quad Gauge Pages (configure which gauges will be displayed) Voltmeter – 12 V / 24 V •...
  • Page 16: Access Levels

    CANplus CP640 - EN Control Panel Operation Manual – RPM Settings Intermediate – Time Profile Warm Up Ramp to Intermediate Ramp to Run Ramp to Cooldown Cooldown Telemetry • Status Address (CAN address for the telemetry device) • Service Timers Timers 1-16 (each timer is listed separately) •...
  • Page 17 CANplus CP640 - EN Control Panel Operation Manual The panel will prompt for a PIN input. User, Tech or Admin level access will be granted based on which PIN is entered. For example, if the Tech level PIN is entered, Tech level access will be granted, and similarly if Admin or User level PINs are entered.
  • Page 18: Manual Operation

    CANplus CP640 - EN Control Panel Operation Manual Manual Operation Use the following steps for manual operation: 1. Ensure that the Auxiliary Engine Stop (if fitted) is not activated. 2. Turn the keyswitch to the run position. 3. Turn the keyswitch clockwise to the start position and hold until the engine successfully starts. 4.
  • Page 19: Rotary Throttle Control

    CANplus CP640 - EN Control Panel Operation Manual Note: Throttle control requires CAN throttling to be enabled in the ECU. CAN throttling is also known as Torque Speed Control or TSC1. When first started, the requested engine speed is Idle RPM. •...
  • Page 20 CANplus CP640 - EN Control Panel Operation Manual Note: The minimum engine speed is controlled by the ECU. Requesting a lower speed causes the engine to run at the ECU minimum speed. RPM limits are configured into the panel to limit the requested speed. Changing the panel’s Minimum Requested RPM and Maximum Requested RPM requires a Tech Level Password or higher in order to access those settings.
  • Page 21 CANplus CP640 - EN Control Panel Operation Manual Once the LED stays solid green, the engine’s RPM can be adjusted as desired. Once the job is complete, pressing the Autoramp™ switch will cause the Autoramp™ LED to blink again and the panel to automatically ramp the engine down following the configured RPM and time profiles.
  • Page 22: Configuration

    The software suite is meticulously maintained and regularly updated. These free updates include software enhancements and new functionality, and they ensure compatibility with evolving technologies. Please see the Resources section at www.cattron.com/cp640. The CANplus Config Kit (Part Number 010-6750-01) includes the following: •...
  • Page 23 CANplus CP640 - EN Control Panel Operation Manual System Install the USB drive in the panel’s USB port. The current configuration can be exported by going to the → Export Config menu. To import a new configuration, the menu access level must be at the Tech or Admin System →...
  • Page 24: Miscellaneous

    CANplus CP640 - EN Control Panel Operation Manual Miscellaneous Emissions System Functionality Note: GENERAL EMISSIONS DISCLAIMER This panel may include provision(s) for operator input such as FORCE REGENERATION, INHIBIT REGENERATION, INTERLOCK and others specific to US and International emissions regulations. Responsibility for emissions-related inputs and compliance with emissions regulations is solely that of the owner and/or operator of the machine/engine on which this panel is connected.
  • Page 25: Typical J1939 Wiring Topology

    CANplus CP640 - EN Control Panel Operation Manual 6.2.1 Typical J1939 Wiring Topology 6.2.2 Engine Harness Connector Connection to the engine is provided by a Deutsch/TE 21 pin connector (Part Number HDP24-24-21PE). The mating connector is Deutsch/TE (Part Number HDP26-24-21SE). Signals are shown in Table Table 1: Engine Harness Connection...
  • Page 26: Sealed Connectors

    Maximum Starter Relay Excitation Current Draw 5 A @ 12 V 3 A @ 24 V Cattron provides suitable heavy duty relays and generic starter relay wiring kits in both 12 V and 24 V; please contact your LOFA reseller for more information.
  • Page 27: Battery Circuit Requirements

    Powering the control system through a 30 A fused dedicated circuit reduces the possibility of system damage. CAUTION DISCONNECTING THE BATTERY WHILE THE ENGINE IS RUNNING MAY RESULT IN DAMAGE TO ELECTRICAL COMPONENTS. WHEN USING A BATTERY DISCONNECT SWITCH, CATTRON RECOMMENDS USING A TWO POLE SWITCH TO DISCONNECT BOTH THE BATTERY AND ALTERNATOR OUTPUT.
  • Page 28: Welding On Equipment With Electronic Controls

    CANplus CP640 - EN Control Panel Operation Manual Inductive devices such as relays, solenoids and motors generate voltage transients and noise in electrical circuits. Unsuppressed voltage transients can exceed SAE specifications and damage electronic controls. Relays and solenoids with built-in voltage transient suppression diodes are recommended whenever possible. Ensure the proper installation of diodes when built-in voltage transient suppression is not available.
  • Page 29: Testing A Warning Or Shutdown

    CANplus CP640 - EN Control Panel Operation Manual Control system performs normal self-test, engine cranks, runs and shuts down Possible Cause Possible Remedy Engine Stop LED illuminated Correct ECU stop condition, use ECU diagnostics Display does not display data Possible Cause Possible Remedy Display lost power Turn on key, verify display plugged into harness...
  • Page 30: Diagnostic Trouble Codes (Dtc)

    CANplus CP640 - EN Control Panel Operation Manual 5. Reinstall the terminator resistor and reconnect the battery. If the ECU diagnostic tool is available, use it to verify that the ECU is transmitting CAN data. Refer to the ECU documentation to identify and correct the error. If another panel is available for testing, replace the panel to determine if the error is in the panel.
  • Page 31 CANplus CP640 - EN Control Panel Operation Manual Description Abnormal frequency, pulse width or period Abnormal update rate Abnormal rate of change Failure mode not identifiable Bad intelligent device or component Out of calibration Special instructions Data valid but above normal operational range (least severe) Data valid but above normal operational range (moderately severe) Data valid but below normal operational range (least severe) Data valid but below normal operational range (moderately severe)
  • Page 32: Technical Support

    CANplus CP640 - EN Control Panel Operation Manual Technical Support For remote and communication control systems support, parts and repair, or technical support, visit us online at: www.cattron.com/contact. 9M02-1000-A001-EN Revision B...
  • Page 33 Cattron Wireless Automation and Control Solutions Support For remote and communication control systems support, parts and repair, or technical support, visit us online at: www.cattron.com/contact Cattron North America Inc., 655 N River Rd NW, Suite A, Warren, OH 44483 9M02-1000-A001-EN Revision B...