Quick Guide - Baumuller b maXX 3000 Instruction Handbook Manual

Hide thumbs Also See for b maXX 3000:
Table of Contents

Advertisement

7.5

Quick guide

The most important operations are summarized below.
Start menu is always the basic menu.
Go back to the basic menu by pressing the ESC key ( T1) several times.
1 Transmit a parameter set from the controller to the Control Panel
h Basic menu
h Sub-menu
h Select data set No. (Select with <<
h Start transmission controller
2 Transmit parameter set from the Control Panel to the controller
h Basic menu
h Sub-menu
h Select existing data set in Control Panel (select with <<
h Start transmission Control Panel
3 Read error list
h Basic menu
h No error
h Error messages existing
4 Reset/quit errors
h Basic menu
h All generated errors are reset with R.Err (T4).
h Only possible, if the Control Panel's write access to the control word is enabled.
5 Change axis (only double axis devices)
h Simultaneous keystroke of << (T2) and >> (T3)
„Parameter
„Load From
Controller"
n Data set empty [empty]
n Used data set [used] is overwritten with security query
„Parameter
„Save To
Controller"
n No parameter set existing
n
T3
switches between
F
transmit data set to the controller flash and
F + R transmit data set tot the controller flash and load in controller RAM
„Drive
Status"
n First entry always error information
Message No errors
„Drive
Status"
n Value 128 and 0 is set in the control word
n Change active axis - display active axis in the middle of the status bar changes
A1
(axis 1)
A2
(axis 2) or vice versa.
Instruction handbook Control Panel BM3000/BM5000
Set"
T2
or >> T3)
Control Panel with OK
Set"
Message: No Parameter Set existing
controller with OK
Display of the error list: Err 0: xxxx
Document No. 5.12068.01
Operation
T4
T2
or >> T3)
T4
Err 1: xxxx, ....
7
57
of 68

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx 5000

Table of Contents