7.4.1.3 Edit parameter value
This menu is available, if
n the previous selected parameter is not read-only and
n the user has set writing access in configuration menu (see
A1
1.1.1
P 018.068.0.0
Speed additional value
controller
>>
<<
ΟΚ
↑
m While editing the parameter the new value is not transmitted to the controller.
m The value is edited character by character.
m The value is checked and transmitted to the controller by a longer keystroke on OK
The display shows a corresponding error message and returns to edit parameter, if a not
valid value was entered, e. g.:
m Hexadecimal numbers (prefix 0x) have a fix length of 4 or 8 digits according to data
Special rules
for editing
m The list of selectable characters contents a space character, if it is a display format
m The display is scrolled, while editing character strings longer than 3 lines.
m It is not possible to change the given display format.
45).
Speed sdditional value controll
T4
P 018.068.0.0
ENTER
100,00 degrees/s
long
↑
keystroke
(> 1 s)
n The keys << PREV (T2) and >> NEXT (T3) edit the selected character.
n The list of selectable characters depends on the cursor position and the display for-
mat of the parameter.
(function ENTER, T4).
A1
1.1.1
Error: out of range
↑
OK
type. The prefix 0x cannot be edited.
without fixed length. This space character deletes all characters on the right side of
the cursor.
Instruction handbook Control Panel BM3000/BM5000
A1
1.1.1
T4
EDIT
EDIT
A1
Speed sdditional value controll
P 018.068.0.0
1000000 degrees/s
<<
↑
Document No. 5.12068.01
Operation
ZWrite-protection–
A1
1.1.1
Speed sdditional value controll
P 018.068.0.0
100,00 degrees/s
<<
>>
↑
OK
1.1.1
>>
OK
7
on page
37
of 68