Wlan Led Is Off; A Lan Led Is Off While A Device Is Connected - NETGEAR Insight Instant AirBridge User Manual

Table of Contents

Advertisement

WARNING:
Power the AirBridge only with an Ethernet cable that is connected from
the LAN1 (PoE-24V) port to the PoE port on the supplied power adapter. Do not use
any other power source such as a PoE switch. The LAN1 (PoE-24V) port is not a
standard PoE port. Using any other power source could damage the device.
• Make sure that the power cable of the power adapter is plugged into a functioning
electrical outlet. If it is plugged into a power strip, make sure that the power strip is
turned on. If it is plugged directly into the wall, verify that the outlet is not switched
off.
If the error persists, a hardware problem might exist. For recovery instructions or help
with a hardware problem, contact technical support at netgear.com/support.

WLAN LED is off

If the WLAN LED is off, check these items, depending on the operation mode of the
AirBridge:
• Master or access point. If the WLAN LED is off on a master or access point, none
of the 5 GHz SSIDs might be enabled. Make sure that at least one 5 GHZ SSID is
enabled. For more information , see Change or configure a new 5 GHz SSID for a
master or access point on page 62.
• Satellite or client bridge. If the WLAN LED is off on a satellite or client bridge, the
satellite did not connect to the master or the client bridge did not connect to the
access point.
Make sure that you configure the satellite or client bridge correctly so that it can
connect to its link partner. For more information, see Configure the AirBridge as a
satellite in a point-to-point setup on page 36 or Configure the AirBridge as a client
bridge on page 42.
For hardware setup troubleshooting information and information about the signal
strength indicator (SSI) LEDs, see the hardware installation guide, which you can
download by visiting netgear.com/support/download/.
If the error persists, a hardware problem might exist. For recovery instructions or help
with a hardware problem, contact technical support at netgear.com/support.

A LAN LED is off while a device is connected

The LAN1 LED and LAN2 LED on the AirBridge function as follows:
• LAN2 LED. The LAN1 (PoE-24V) port on the AirBridge must always be connected
to the supplied power adapter. If the LAN port on the power adapter is not connected
to an Ethernet device, the LAN1 LED on the AirBridge remains off. This is normal
Perform Diagnostics and
Troubleshooting
Insight Instant AirBridge WBC502 User Manual
137
User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbc502

Table of Contents