Further details regarding the individual steps
Checking the burner gasket and burner gauze assembly
Check burner gasket A for damage
and replace if necessary.
B
1. Remove electrode B.
2. Undo 2 Torx screws. Remove ther-
mal insulation ring C.
3. Undo 2 Torx screws. Remove
burner gauze assembly D with
gasket E.
Commissioning, inspection, maintenance
Replace the burner gauze assembly if it
is damaged.
D
E
4. Insert and secure new burner
gauze assembly D with new gas-
ket E.
5. Mount thermal insulation ring C.
(cont.)
A
C
47