SICK ReLy OSSD4 Operating Instructions Manual

SICK ReLy OSSD4 Operating Instructions Manual

Safety relay
Hide thumbs Also See for ReLy OSSD4:

Advertisement

O P E R A T I N G I N S T R U C T I O N S
ReLy OSSD4
Safety relay
RLY3-OSSD400S14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReLy OSSD4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK ReLy OSSD4

  • Page 1 O P E R A T I N G I N S T R U C T I O N S ReLy OSSD4 Safety relay RLY3-OSSD400S14...
  • Page 2 Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 3: Table Of Contents

    Disassembly....................Module exchange..................Electrical installation................ 18 Device connection..................8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 4 List of figures..................29 List of tables..................30 O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 5: Ordering Information

    ReLy OSSD4 Opto-electronic protec‐ RLY3-OSSD400S14 1112276 tive devices 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 6: About This Document

    Data sheets and application examples • CAD data and dimensional drawings O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 7: Symbols And Document Conventions

    Ö The LED is flashing. O The LED is illuminated continuously. 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 8: Safety Information

    At altitudes of over 4,000 m above sea level • In explosion-hazardous areas O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 9: Requirements For The Qualification Of Personnel

    8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 10: Product Description

    (OSSD) and safety controllers with monitored semiconductor outputs O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 11: External Device Monitoring

    Further topics • "Status indicator (LED)", page 21 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 12: Project Planning

    Sufficient distance must be kept for the connected cables before the module (front side). O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 13: Electrical Integration

    State of feedback current path Closed Open Open Closed 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 14: Connection Diagrams

    6, page O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 15: Mounting

    Figure 5: Mounting Attach module to mounting rail. 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 16: Disassembly

    Figure 7: Dismantle front connector O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 17: Mount The Front Connector

    The front connector engages with an audible click. 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 18: Electrical Installation

    ISO 13849-1 and SILCL in accordance with IEC 62061 (e.g. shielded single sheathed cables, separate installation). O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 19: Terminals On Front Connector

    Further topics • "Connection diagrams", page 14 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 20: Commissioning

    The thorough checks must be carried out by qualified safety personnel or specially qualified and authorized personnel, and must be documented in a traceable manner. O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 21: Troubleshooting

    Voltage on I1 Voltage on I2 O Green 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 22: Decommissioning

    SICK will be glad to help you dispose of these devices on request. O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 23: Technical Data

    Fine wire with ferrules with or without collar 0.25 mm … 1.0 mm (1×) 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 24 Contact fuse with safety fuse gG or circuit Max. 6 A breaker C O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 25 Figure 10: Switch-off delay without continuous arcing Inductive load L/R 40 ms Resistive load 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 26: Dimensional Drawings

    30,1 87,7 85,5 78,7 Figure 12: Dimensional drawing O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK Subject to change without notice...
  • Page 27: Internal Circuitry

    TECHNICAL DATA 11.3 Internal circuitry Figure 13: Internal circuitry 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 28: Annex

    (part number: see the type label entry in the “Ident. no.” field). O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 29: List Of Figures

    12. Dimensional drawing....................26 13. Internal circuitry......................27 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 30: List Of Tables

    (51, 52) and feedback current path (61, 62)........24 10. Ambient data.......................25 O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 8026008/2020-07-28 | SICK...
  • Page 31 LIST OF TABLES 8026008/2020-07-28 | SICK O P E R A T I N G I N S T R U C T I O N S | ReLy OSSD4 Subject to change without notice...
  • Page 32 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

This manual is also suitable for:

Rly3-ossd400s14

Table of Contents

Save PDF