Sony PDW-U4 Service Manual page 54

Professional disc drive unit
Hide thumbs Also See for PDW-U4:
Table of Contents

Advertisement

Main
Sub
ERROR/ALARM indicator
Code
Code
Lighting
Switching off
interval
condition
91
5A5
0.25 seconds
Power
5A7
0.25 seconds
Power
5B5
0.25 seconds
Power
5B7
0.25 seconds
Power
Description
Error remedy method
Communication between
Turn off and on the unit, and then perform again firmware update.
Disc Drive LSI 0b
The unit power may have been shut down during firmware update.
(IC200: BD-48 board)
If the same error occurs, a drive fault is likely.
and BRIDGE (IC700
internal: BD-48 board)
cannot be established
during startup.
Failure in Disc Drive LSI
0b (IC200: BD-48 board)
firmware upgrade was
detected during startup.
Communication between
Disc Drive LSI 1a
(IC300: BD-48 board)
and BRIDGE (IC700
internal: BD-48 board)
cannot be established
during startup.
Failure in Disc Drive LSI
1a (IC300: BD-48 board)
firmware upgrade was
detected during startup.
Refer to section
"Section 5 Firmware Update"
Continued
51

Advertisement

Table of Contents
loading

Table of Contents