Backwashable Filter Setting Options - Water Depot ECONO Series Owner's Manual

Backwashable filter
Table of Contents

Advertisement

Gallons
Regeneration
Capacity
Time Option
oFF
NORMAL
Any
NORMAL
number
Any
NORMAL
number
Any
On O
number
Any
NORMAL on
number
0
General Operation
When the system is operating, one of five displays may be
shown. The displays normally rotate, however pressing NEXT
will pause on the selected display for 5 minutes. Pressing NEXT
will alternate between the displays. One of the displays is
always the current time of day. The second display is one of the
following: days remaining or volume remaining. Days remaining
is the number of days left before the system goes through a
regeneration cycle. Capacity remaining is the gallons that will
be treated before the system goes through a regeneration cycle.
Pressing the  button whi l e in the Capacity Remaining display
will decrease the capacity remaining in 10 gallon increments and
will also increase the volume used impacting the recorded values
in Diagnostics Steps 3D, 4D and 5D and Valve History, Step 4VH.
The third display shows the current treated water flow rate
through the system. The fourth display will show either dP or
hold if the dP switch is closed. The fifth display indicates the
user should call for service. The fifth display will not appear if
OFF is selected in Step 13S of Softener System Setup or
Step 12F of Filter System Setup. To clear the Service Call
reminder, press the  a nd  buttons s imulta ne ous ly while
CALL
is displayed.
If the system has called for a regeneration that will occur at the
preset time of regeneration, the words REGEN TODAY will
appear on the display.
If a water meter is installed, the word "Softening" or "Filtering"
flashes on the display when water is being treated (i.e. water is
flowing through the system).

Backwashable Filter Setting Options

Day
Override
Reserve capacity not automatically estimated.
Any
Regeneration occurs at the next Regen Set Time when the
number
specified number of days between regenerations is reached.
Reserve capacity not automatically estimated.
oFF
Regeneration occurs at the next Regen Set Time when gallons
capacity reaches 0.
Reserve capacity not automatically estimated.
Any
Regeneration occurs at the next Regen Set Time when gallons
number
capacity reaches 0 or the specified number of days between
regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
oFF
Time of regeneration will not be allowed to be set because
regeneration will always occur on 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the
Any
specified number of days between regenerations is reached or
number
regeneration occurs immediately after 10 minutes of no water
usage when gallon capacity reaches 0.
User Display Settings
Result
10