Step 7F – Set Volume Capacity using the  or  button. If value is set to:
• "oFF" regeneration will be based solely on the day override set (see Installer Display/Settings
Step 3I); or
• as a number (allowable range 20 to 250,000) regeneration initiation will be based off the
value specified. Increment increase is 20 for the range 20 to 2,000, 100 for the range of 2,000
to 10,000, 500 for the range 10,000 to 50,000 and 2,000 for the range of 50,000 to 250,000.
See Table 9 for more detail. Press NEXT to go to Step 8F. Press REGEN to return to previous
step.
Step 8F – Set Regeneration Time Options using the  or  button. If value is set to:
• "NORMAL" means regeneration will occur at the preset time;
• "on 0" means regeneration will occur immediately when the gallons capacity reaches 0
(zero); or
• "NORMAL + on 0" means regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve or the specified number of
days between regenerations is reached whichever comes first; or
— after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See Table 9 for more detail. Press NEXT to go to Step 9F. Press REGEN to return to previous
step.
STEP 8F
Displays 9F, 10F and 11F are unique to the V3353HR WS1HR PC Board w/Relay. See
WS1HR&HS & WS1.25HR&HS Front Cover and Drive Assembly diagram. If using a CLK
V3353HS WS1HS PC Board proceed to Step 12F.
Step 9F: Set Relay operation using the  or  button. The choices are:
• Set Time on: Relay activates after a set time at the beginning of a regeneration and then
deactivates after a set period of time. The start of regeneration is de. ned as the . rst backwash
cycle, Dn brine cycle or UP brine cycle which ever comes . rst.
• Set Gal on: Relay activates after a set number of gallons has been treated and then
deactivates after a set period of time or after the meter stops registering . ow, whichever comes
. rst.
• Off: If set to Off, Steps 10F and 11F will not be shown.
Press NEXT to go to Step 10F. Press REGEN to return to previous step.
Step 10F: Set Relay Actuation Time or Gallons using the  or  buttons. The choices are:
• Relay Actuation Time: After the start of a regeneration the amount of time that should pass
prior to activating the relay. The start of regeneration is de. ned as the . rst backwash cycle, Dn
brine cycle or UP brine cycle which ever comes . rst. Ranges from 1 second to 200 minutes.
•Relay Actuation Gallons: Relay activates after a set number of gallons has passed through the
meter when the valve is in the Service mode. Ranges from 1 to 50 gallons.
Press NEXT to go to Step 11F. Press REGEN to return to previous step.
Step 11F: Set Relay Deactivate Time using the  or 
• If Set Time on is selected in Step 9F the relay will deactivate after the time set has expired.
Ranges from 1 second to 200 minutes.
• If Set Gal on is selected in Step 9F the relay will deactivate after the time set has expired or
after the meter stops registering . ow, whichever comes . rst. Ranges from 1 second to 20
minutes.
Press NEXT to go to Step 12F. Press REGEN to return to previous step.
Step 12F: Set the Service Call Indicator by using the 
 buttons.
Range is in ¼ of a year increments from 0.25 to 9.75 years. Selecting
OFF will disable this feature. Press NEXT to exit Filter System
Setup. Press REGEN to return to previous step.
buttons.
or
9