Softener Setting Options - Water Depot PLATINUM SERIES Owner's Manual

Hide thumbs Also See for PLATINUM SERIES:
Table of Contents

Advertisement

ns
Regeneration
Capacity
Time Option
AUTO
NORMAL
AUTO
NORMAL
Any
NORMAL
number
oFF
NORMAL
Any
NORMAL
number
AUTO
On O
Any
On O
number
AUTO
NORMAL on 0
AUTO
NORMAL on 0
Any
NORMAL on 0
number
8
Reserve capacity estimate is based on history of water usage.
Step 10S: Set the Service Call Indicator by using the
in ¼ of a year increments from 0.25 to 9.75 years. Selecting OFF will disable this
feature. Press NEXT to exit Softener System Setup. Press REGEN to return
to previous step.

SOFTENER SETTING OPTIONS

Day
Override
Reserve capacity automatically estimated.
oFF
Regeneration occurs when gallons capacity falls below the reserve
Capacity at the next Regen Set Time.
Reserve capacity automatically estimated.
Any
Regeneration occurs at the next Regen Set Time when gallons capacity
number
falls below the reserve capacity or the specified number of days between
regenerations is reached.
Reserve capacity not automatically estimated.
oFF
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0.
Reserve capacity not automatically estimated.
Any
Regeneration occurs at the next Regen Set Time when the specified
number
number of days between regenerations is reached.
Reserve capacity not automatically estimated.
Any
Regeneration occurs at the next Regen Set Time when gallons capacity
number
reaches 0 or the specified number of days between regenerations is
reached.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
oFF
Time of regeneration will not be allowed to be set because regeneration
will always occur when gallons capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
oFF
Time of regeneration will not be allowed to be set because regeneration
will always occur on 0.
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
oFF
capacity at the next Regen Set Time or regeneration occurs immediately
after 10 minutes of no water usage when gallon capacity reaches 0.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
Any
falls below the reserve capacity or the specified number of days between
number
regenerations is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified
Any
number of days between regenerations is reached or regeneration
number
occurs immediately after 10 minutes of no water usage when gallon
capacity reaches 0.
Page 8
or
buttons. Range is
8
Result