Setup Barcode Position - IDEC WB1F Series User Manual

Fix linear ccd scanner
Hide thumbs Also See for WB1F Series:
Table of Contents

Advertisement

1. Overview
Installation & wiring
2. 2. 2

Setup barcode position

Install the unit so that barcode skew θ is in the range of -20° ≤ θ ≤ 0° and +20° ≤ θ ≤ +40°.
For the reading area, refer to
Angular
characteristics". For detailed dimensions, refer to
Skew in a range of 0° < θ < 20° is in the mirror reflection area (dead zone), so reading performance may dras-
z
tically decrease in ways such as the unit not being able to read or misreading barcodes.
Install the unit so the light receiving axis is in the center of the barcode.
z
The unit may not be able to read barcodes that are short in height as they will not be in the light receiving
z
axis.
Ensure that the barcode height is 3 mm or higher.
F P. 3-31 "3. 3. 2 Setup support function"
ing rate.
3. Functions
F P. 5-2 "5. 2. 1 Field of
θ
-
+
Mirror reflection area (dead zone)
-20 to 0°
+20 to +40°
10°
Barcode
4. Support tool
view". For other angular characteristics, refer to
F P. 5-4 "5. 3 Dimensional outline
Do not read barcodes in the skew range 0° < θ <
20°.
Setup barcode position range
Light receiving axis
* The light receiving axis is the path where the reflected
light from the barcode travels to create an image on
the WB1F internal CCD. The unit reads barcodes that
are on the light receiving axis.
to adjust the istallation position while checking the barcode read-
5. Appendix
Mounting methods
F P. 5-3 "5. 2. 2
drawings".
2-4