2. 4-Way Air Discharge Semi-concealed Type
2-3. Other component specifications
MODEL NO.
Power Transformer
1
Rated
Primary
Secondary
Coil resistance
Thermal cut off temperature
Thermistor (Coil sensor)
Resistance
Thermistor (Room or coil sensor)
Resistance
Electronic expansion valve
Valve body
Coil
Drain pump
Rated
Float switch
Rated (Contact rated)
Indoor Unit
V, Hz
Ω
˚C
KΩ
KΩ
ECO MULTI SYSTEM Unit Spesifications
SPW-XR123 ~ 483GH56
ATR-II215TA
AC 230 V, 50 Hz
10.2 V 1.4 A
14 V 0.5 A
WHT – WHT : 84
RED – RED : 2.7
PB3M-41E-S4 , PBC-41E-S25 , PBC-41E-S26 , PBC-41E-S36
-10 ˚C : 23.7 ± 5 %
-5 ˚C : 18.8 ± 5 %
0 ˚C : 15.0 ± 5 %
5 ˚C : 12.1 ± 5 %
10 ˚C : 9.7 ± 5 %
KTEC-35-S6
0 ˚C : 16.5 ± 5 %
5 ˚C : 12.8 ± 5 %
10 ˚C : 10.0 ± 5 %
20 ˚C : 6.3 ± 5 %
30 ˚C : 4.0 ± 5 %
IKV-24D12 (SPW-XR123 ~ 253GH56)
HKV-30D16 (SPW-XR363 · 483GH56)
DKV-MOZS582E0 (SPW-XR123 ~ 253GH56)
EKV-MOZS584E0 (SPW-XR363 · 483GH56)
WP20SL-21
AC 230 V, 14.7 W
FS-0218-102 (SPW-XR123 ~ 253GH56)
FS-0218-103 (SPW-XR363 · 483GH56)
DC 12 V, 25 W
I - 32
,
BRN – BRN : 0.7
150
20 ˚C : 6.5 ± 5 %
,
30 ˚C : 4.4 ± 5 %
,
40 ˚C : 3.1 ± 5 %
,
45 ˚C : 2.6 ± 5 %
,
40 ˚C : 2.7 ± 5 %
,
45 ˚C : 2.2 ± 5 %
,
50 ˚C : 1.8 ± 5 %
,
55 ˚C : 1.5 ± 5 %
,
SM830063