Other Component Specifications - Sanyo SAP-C302AH-S Technical & Service Manual

Table of Contents

Advertisement

2-3. Other Component Specifications

Indoor Unit
SAP – K302AH
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Thermistor (Coil sensor)
Resistance
Thermistor (Room sensor)
Resistance
Outdoor Unit
SAP – C302AH
4-way Valve (RV)
Coil rating
Thermistor (Coil sensor)
Resistance
Thermistor (Air sensor)
Resistance
Power Relay (PR)
Coil rating
Contact rating
Fuse
Rating / Size
Primary
Secondary
Capacity
Ω (at 21°C)
kΩ
kΩ
kΩ
kΩ
AC 230V, 50 / 60 Hz
Primary (WHT – WHT):
Secondary (BRN – BRN):
DTN-TKS131B
0°C
DTN-TKS128B
25°C
CHV-01AJ504D1 (Coil), STF-03U1 (Valve)
AC 220–240V, 50Hz, 6W
PBC – 41E – S14
– 20°C 40.1± 5%
– 10°C 24.4 ± 5%
0°C 15.3 ± 5%
10°C 9.9 ± 5%
PBC – 41E – S14
– 20°C 40.1± 5%
– 10°C 24.4 ± 5%
0°C 15.3 ± 5%
10°C 9.9 ± 5%
AC 200 – 240V, 50/60Hz
AC 277V, 30A
Cartridge type
250V, 20A / ø6.4 x 30mm
5
ATR-J105-I
19V, 0.526A
10VA
205 ± 10%
2.0 ± 10%
150°C
15.0 ± 2%
5.0 ± 3%
20°C 6.5 ± 5%
30°C 4.4 ± 5%
40°C 3.0 ± 5%
50°C
2.1± 5%
20°C 6.5 ± 5%
30°C 4.4 ± 5%
40°C 3.0 ± 5%
50°C
2.1± 5%
EL1U

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-k302ah-sSap-k302ahSap-c302ah185208378185208419

Table of Contents