Other Component Specifications - Sanyo SPW-CR363GVH8 Service Manual

Table of Contents

Advertisement

11. 1-Way Air Discharge Semi-concealed-Slim Type (SL Type)

11-3. Other component specifications

MODEL NO.
Indoor Unit
Power Transformer
Rated
Primary
Secondary
Coil resistance
Thermal cut off temperature
Thermistor (Coil sensor)
Resistance
Thermistor (Room or coil sensor)
Resistance
Electronic expansion valve
Valve body
Coil
Drain pump
Rated
Float switch
Rated (Contact rated)
ECO MULTI SYSTEM Unit Specifications
SPW-SLR93 ~ 253GH56
V, Hz
WHT - WHT : 112
RED - RED :
˚C
PB3M-41E-S4 , PBC-41E-S25 , PBC-41E-S36
-10 ˚C : 23.7 ± 5 %
KΩ
-5 ˚C : 18.8 ± 5 %
0 ˚C : 15.0 ± 5 %
5 ˚C : 12.1 ± 5 %
10 ˚C : 9.7 ± 5 %
0 ˚C : 16.5 ± 5 %
KΩ
5 ˚C : 12.8 ± 5 %
10 ˚C : 10.0 ± 5 %
20 ˚C : 6.3 ± 5 %
30 ˚C : 4.0 ± 5 %
I - 143
ATR-II215TB
AC 230 V, 50 Hz
10.2 V, 1.4 A
14 V, 0.5 A
BRN - BRN :
2.3
150
20 ˚C : 6.5 ± 5 %
,
30 ˚C : 4.4 ± 5 %
,
40 ˚C : 3.1 ± 5 %
,
45 ˚C : 2.6 ± 5 %
,
KTEC-35-S6
40 ˚C : 2.7 ± 5 %
,
45 ˚C : 2.2 ± 5 %
,
50 ˚C : 1.8 ± 5 %
,
55 ˚C : 1.5 ± 5 %
,
IKV-24D12
DKV-MOZS550E0
WP20SL-19
AC 230 V, 14.7 W
FS-0218-103
DC 12 V, 25 W
1
0.5
SM830063