2-3. Other Component Specifications

Indoor Unit
SAP – K71GH
SAP – K91GH
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Thermistor (Coil sensor)
Resistance
Thermistor (Room sensor)
Resistance
Outdoor Unit
SAP – C71GH
SAP – C91GH
Power Relay (PR)
Coil rating
Coil resistance
Contact rating
Thermostat (Defrost thermo. 23D)
Operating temp.
4-way Valve (20S)
Coil rating
Coil resistance
Primary
Secondary
Capacity
Ω (at 21°C)
kΩ
kΩ
Ω (at 20°C)
°C
Ω (at 20°C)
AC 230V, 50 / 60 Hz
Primary (WHT – WHT):
Secondary (BRN – BRN):
DTN-TKS131B
0°C
DTN-TKS128B
25°C
DFU24D1-F (M)
TRS02-12MSR
ON
Diff.
LB81012 (Coil), VK1100B (Valve)
AC 220/240V, 50/60Hz, 6W
8
ATR-J105
19V, 0.526A
10VA
205 ± 10%
2.0 ± 10%
150°C
15.0 ± 2%
5.0 ± 3%
DC 24V
650 ± 10%
AC 250V, 20A
12 ± 2
8 deg. below
3,030 ± 7%