6. Ceiling Mounted Type
Indoor unit (B)
MODEL No.
Source
Controller P.C.B. Ass'y
1
Fan (Number...diameter)
Fan motor
Model...Nominal output
Source
No. of pole...r.p.m. (230 V, High)
Coil resistance
(Ambient temperature 20 °C)
Safety device
Operating temperature
Run capacitor
Electronic expansion valve
Coil
Coil resistance (at 20 °C)
Valve body
Heat exchanger
Coil
Rows...fin pitch
Face area
Auto louver motor
Auto louver motor...Rated
Coil resistance (at 25 °C)
ECO MULTI SYSTEM Unit Specifications
mm
W
rpm.
BRN – WHT : 111.0
WHT – VLT
VLT – ORG :
Open °C
Close °C
VAC, µF
ORG – GRY : 46 ,
RED – GRY : 46 ,
mm
m
2
V, Hz, W, rpm.
I - 74
SPW-TR253GH56
220 - 230 - 240 V / 1 phase / 50 Hz
CR-X253GH (Microprocessor)
Centrifugal (4 ... ø 130)
SR4X-51A6P ... 50 W
220 - 230 - 240 V / 1 phase / 50 Hz
4 ... 1,172
ORG – YEL
:
35.4
YEL – BLK
13.4
BLK – PNK
130 ±
8
( 79 ± 15 )
440 V, 1.5 µF
DKV - MOZS582E0
YEL – GRY : 46
BLK – GRY : 46
IKV-24D12
Aluminum plate fin / Copper tube
3 ... 1.7
0.168
MT8 - 3C
220 – 240 VAC, 50 Hz, 3 W, 2.5 rpm.
16.430 Ω ± 8 %
:
16.7
: 136.6
:
23.9
SM830063