Product Quick Reference Card
Device Maintenance
Battery Replacement
Materials:
Small Phillips Head Screwdriver
Replacement Battery (U9VL-J)
- Puncture the center of the back label with the screw driver
and unscrew the enclosure.
- Remove the battery by pulling it perpendicular to the circuit
board.
- Insert the new battery into the terminals and verify it is secure.
- Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT
SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE,
CRUSH, PENETRATE OR INCINERATE. BATTERY MAY LEAK OR
EXPLODE IF HEATED ABOVE 60°C (140°F).
Recalibration
The RFpHTemp101A standard calibration is performed at 50
Ohms and 150 Ohms for the RTD channel and 0mV and 250mV
for the pH channel.
Note: MadgeTech does not offer calibration of pH inputs in
combination with a pH electrode or probe.
Pricing:
Recalibration traceable to NIST
$90.00
Recalibration
$70.00
Additional:
As Found Data
$15.00 per parameter/channel
Verification Point
$15.00 per point
To send the devices back, visit www.madgetech.com, select
Services then RMA Process.
Part Number
RFpHTemp101A
pH Measurement Range
0 to 14pH
pH Measurement Resolution
0.01 pH
pH Measurement Accuracy
+0.1 pH
RTD Measurement Range
-0 to +100°C
RTD Measurement Resolution
0.01°C
RTD Measurement Accuracy
+0.1°C @ 25°C
Memory
13,107/channel
Sample Rate
30 seconds up to 12 hours
LED
Red & Greem
Required Interface Package
RFC101A
PC Baud Rate
57,600
RF Carrier Frequency
418 + 0.075MHz
RF Baud Rate
4,800
RF Range
Typical Outdoors/Line of Sight: Up to 120' (36m)
Typical Indoors/Urban: Up to 40' (12m)
Typical Battery Life
1 Year
Material
ABS Plastic
Operating Environment
-5 to +50°C, 0 to 95%RH (Non-Condensing)
Dimensions
4.5" x 2.4" x 1.0" plus 2.0" Antenna
(114mm x 61mm x 26mm plus 51mm Antenna)
Approvals
US (FCC), CA (IC)
Specifications subject to change.
See MadgeTech's terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50
Warner, NH 03278
l
Phone 603.456.2011
Fax 603.456.2012
l
www.madgetech.com
info@madgetech.com
l
Product Information Card
RFpHTemp101A
Precision RTD Temperature Recorder and Wireless Transmitter
REV D 2009.06.11
RFpHTemp101A
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at
www.madgetech.com.

Advertisement

loading

Summary of Contents for MadgeTech RFpHTemp101A

  • Page 1 Ohms and 150 Ohms for the RTD channel and 0mV and 250mV Typical Indoors/Urban: Up to 40’ (12m) for the pH channel. Typical Battery Life 1 Year Note: MadgeTech does not offer calibration of pH inputs in combination with a pH electrode or probe. Material ABS Plastic Operating Environment -5 to +50°C, 0 to 95%RH (Non-Condensing)
  • Page 2 5. Refer to the description of your pH probe - At this point, communications have been configured for your 3-Measurement (+) Input Visit www.madgetech.com, or call (603) 456-2011. 2- Measurement(-) Input for a calibration procedure. logger. These settings can be found under the Communication...