ABB Welcome IP H8236 Series Product Manual page 49

Ip touch
Hide thumbs Also See for Welcome IP H8236 Series:
Table of Contents

Advertisement

Assigning the "Turn on the light" function
Please follow the steps to assign the address:
[1] On the "System settings" screen, tap "Door Entry System".
[2] Select "Turn on the light" from the drop-down list.
[3] Select the IP actuator type from the drop-down list. It can be set to "Network IP actuator",
"Building IP actuator" or "Private IP actuator".
[4] Enter the device number.
Note
If IP actuator need to be assigned the function, a gate station (device ID =1)
must be used before assignment.
If building IP actuator need to be assigned the function, a building outdoor
station (device ID =1) must be used before assignment.
Product manual 2TMD041800D0002
Commissioning
│49