Download Print this page

Electrical Requirements; Gas Supply Requirements - Dacor Heritage HDCT304 Series Planning Manual

30”, 36” dual cooktop
Hide thumbs Also See for Heritage HDCT304 Series:

Advertisement

HDCT304, HDCT365

Electrical Requirements

To prevent electric shock, the power supply must meet the given
specifications. The owner shall ensure that the electrical service meets
requirements and that the power outlet is properly installed by a
licensed electrician.
• The cooktop has a 40-in.power cord with 3-prong grounding plug on
the chassis' bottom right-rear corner.
• The cooktop must be connected to a dedicated, grounded 3-prong
electrical outlet installed by a licensed electrician.
• The electrical installation, including supply-wire size and grounding,
must be done according to National Electric Code ANSI/NFPA 70* and
local codes and ordinances. A copy of this standard is available from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
• The correct voltage, frequency, and amperage must be supplied to the
electrical outlet according to the data label (see previous graphic).
• See the Gas/Electrical Requirements table (this page).
• Choose an easily accessible electrical outlet so the cooktop can be
unplugged for service/maintenance.
All specifications subject to change without notice.
Heritage
®
WARNING
HDCT304
HDCT365
30", 36" Dual Cooktop
Gas-Supply Requirements
• Ensure the cooktop is correct for the gas (natural or liquid propane)
provided. If using the cooktop above 4000 ft. (1219 m) elevation,
ensure it is equipped for high-elevation operation.
• Units equipped for liquid propane have "LP" in the model number on
the product data label (previous graphic).
• Units equipped for high-elevation use have an "H" at the end of the
model number on the product data label.
• Install the cooktop according to local building codes; if none exist,
install the appliance according to the National Fuel Gas Code ANSI
Z223.1/NFPA 54.
• An external manual shut-off valve must be installed between the gas
inlet and cooktop so gas to the appliance can be turned on/off.
• The cooktop comes with its own regulator, which must be installed in
the gas line from the cooktop gas inlet to the gas shut-off valve. Use
only the regulator provided.
• The cooktop has a 3/4-in. regulator approved for connection to a 1/2-in.
house gas supply.
• The cooktop gas connection is on the chassis bottom in the right-rear
corner (previous graphic).
Gas and Electrical Requirements*
Data Type*
Gas type
Manifold pressure
Min. gas-supply pressure**
Max. gas-supply pressure
Total connected load
Circuit requirement
*This data is for reference only. If it does not agree with the product data label,
use the data on the product data label; **the gas-supply pressure for testing
the regulator setting shall be at least 1" water column (249 Pa) above the
specified manifold pressure.
www.dacor.com
All tolerances: ±¹/₁₆" (±1.6 mm) unless otherwise stated.
PLANNING
HDCT304/NG,
HDCT365/NG
Natural Gas
5" water column
6" water column
0.25 Amp. (0.03 kW)
120 Vac, 60 Hz, 15 Amp
Page 3 of 5
GUIDE
HDCT304/LP,
HDCT365/LP
LP Gas
10" water column
11" water column
1/2 psi
Ph. 800.793.0093

Advertisement

loading

This manual is also suitable for:

Heritage hdct365 seriesHeritage hdct304/ngHeritage hdct365/ngHeritage hdct304/lpHeritage hdct365/lp