Guidance and Manufacturer's Declaration — Electromagnetic Immunity
The SC-2004-OC/SC-2004FC-OC/SC-2008-OC are intended for use in the electromagnetic environment specified below. The customer or the
user of the SC-2004-OC/SC-2004FC-OC/ C-2008-OC should assure that it is used in such an environment.
Immunity
IEC 60601 test
test
level
Conducted RF
3 Vrms
IEC 61000-4-6
15 kHz to 80
MHz
Radiated RF
3 V/m
IEC 1000-4-3
80 MHz to 2.5
GHz
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply to all situations. Electromagnetic propagations is affected by absorption and reflections from struc-
tures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur ra-
dio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environ-
ment due to fixed RF
transmitters, an electromagnetic site survey should be considered. if the measured field strength in the location in which the model SC-
2004-OC/SC-2004FC-OC/SC-2008-OC is used exceeds the applicable RF compliance level above, the model SC-2004-OC/SC-2004FC-OC/SC-
2008-OC should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary,
such as re-orienting or relocating the model SC-2004-OC/SC-2004FC-OC/SC-2008-OC.
b
Over the frequency range 150 kHZ to 80 MHz, field strengths should be less than 3 V/m.
Model SC-2004-OC/SC-2004FC-OC/SC-2008-OC Electromagnetic Emissions—Manufacturer's Declaration
The SC-2004-OC/SC-2004FC-OC/SC-2008-OC are intended for use in the electromagnetic environment specified below. The customer or the
user of the SC-2004-OC/SC-2004FC-OC/SC-2008-OC should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations / flicker
emissions
IEC 61000-3-3
Compliance level
3 Vrms
Portable and mobile RF communications equipment should be used no closer to any
part of the model SC-2004-OC/SC-2004FC-OC/SC-2008-OC, than the recommended
separation distance calculated from the equation applicable to the frequency of the
3 V/m
transmitter.
Recommended separation distance
where P is the maximum output power rating of the transmitter in watts (W) accord-
ing to the transmitter manufacturer and d is the recommended separation distance
in meters (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site
survey,
Interference may occur in the vicinity of equipment marked with the following sym-
bol:
Compliance
Group 1
The model SC-2004-OC/SC-2004FC-OC/SC-2008-OC uses RF energy only for its internal
functions. Therefore, its RF emissions are very low and are not likely to cause any inter-
ference in nearby electronic equipment.
Class B
Not applicable
The model SC-2004-OC/SC-2004FC-OC/SC-2008-OC is suitable for use in all establish-
ments, including domestic establishments and those directly connected to the public
low voltage power supply network that supplies building used for domestic purposes.
Not applicable
Electromagnetic environment—guidance
80 MHz to 800 MHz
800 MHz to 2.5 GHz
a
should be less than the compliance level in each frequency range.
Electromagnetic environment— guidance
b

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC-2004-OC and is the answer not in the manual?

Questions and answers

richard d bernarde
April 4, 2025

What is cost and is it covered by humana honor insurance?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sc-2004fc-ocSc-2008-oc

Table of Contents

Save PDF