Bio Compression Systems SC-2004 Operating Instructions Manual

Bio Compression Systems SC-2004 Operating Instructions Manual

Sequential circulators

Advertisement

SEQUENTIAL
SEQUENTIAL
CIRCULATORS
CIRCULATORS
MODEL 2004
MODEL 2004
MODEL 3004
MODEL 3004
BIO COMPRESSION SYSTEMS, INC.
www.biocompression.com
Phone: 800-888-0908

Advertisement

Table of Contents
loading

Summary of Contents for Bio Compression Systems SC-2004

  • Page 1 SEQUENTIAL SEQUENTIAL CIRCULATORS CIRCULATORS MODEL 2004 MODEL 2004 MODEL 3004 MODEL 3004 BIO COMPRESSION SYSTEMS, INC. www.biocompression.com Phone: 800-888-0908...
  • Page 2 Congratulations on the purchase of your BIO COMPRESSION SYSTEMS MODEL 2004 /MODEL 3004 SEQUENTIAL CIRCULATOR SYSTEM. The durable, high quality material used in the manufacturing of this product will ensure you long lasting performance. On rare incidences when problems occur, you...
  • Page 3 INSTRUCTION/INTENDED USE The Models SC-2004 and SC-3004 are manual (not software driven) sequential, pneumatic compression devices intended for either primary or adjunctive treatment of primary or secondary Lymphedema. These devices are also intended for additional or alternative treatment of venous insufficiency and venous stasis ulcers associated with venous insufficiency as well as general treatment for swelling of the extremities.
  • Page 4: General Equipment Specifications

    CONTRAINDICATIONS • INFECTIONS IN THE LIMB WITHOUT APPROPRIATE ANTIBIOTIC COVERAGE, INCLUDING CEL- LULITIS • THE PRESENCE OF LYMPHANGIOSARCOMA • DEEP VEIN THROMBOSIS (DVT) • INFLAMMATORY PHLEBITIS OR EPISODES OF PULMONARY EMBOLISM • CONGESTIVE HEART FAILURE GENERAL EQUIPMENT SPECIFICATIONS Model # 2004 Segmental, Pneumatic Compression Device with Factory Set Gradient Pressures DIMENSIONS - H X W X D in INCHES 5.5 x 12 x 8 WEIGHT...
  • Page 5: Controls And Indicators

    CONTROLS AND INDICATORS 1) AMBER LIGHTED “ON / OFF” PUMP SWITCH 2) PRESSURE ADJUSTMENT KNOB, LOCKING To prevent against involuntary changes in the pressure setting due to inadvertent movement of the Pressure Adjustment Knob, a new “locking” Pressure Adjustment Knob has been implemented on all model pumps to provide for safer, more effective therapy.
  • Page 6: Electrical Specifications

    UPPER EXTREMITY GARMENT WITH TUBING PLUG/CONNECTOR 8) TUBING PLUG/S 9) LEFT (black) AND RIGHT (white) LOCKING PINS ADJUSTABLE GRADIENT PRESSURE NOTE: When a pressure adjustment is made to any Individual chamber, one must be conscious of the overall Gradients across all chambers so as not to create reverse Gradients ELECTRICAL SPECIFICATIONS The Models 2004 and 3004, Sequential Circu tor’s electrical pumps and components are “double insulated”...
  • Page 7: Fuse Replacement

    NOTE: The outer safety fuse is the only item serviceable by some one other than a Bio Compression Sys- tems technician at the factory. Bio Compression Systems technicians have been trained specifically for the manufacturing and repair of all Bio Compression Systems products.
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS Having familiarized yourself with the controls and features of this equipment, you are now ready to begin your treatment according to your physician’s prescribed course of therapy. Make sure that your circulator is plugged into a safe, properly secured, 110 V, AC outlet. Place unit on a sturdy table or other type surface close to where you will be sitting.
  • Page 9 GARMENT SPECIFICATIONS MATERIAL: #306 Royal Blue, 200 DenierNylon 3.0 oz. Poly-Ether-Urethane Coating Antimicrobial ● Water Repellent Stain Resistant ● Fire Retardent.Cal.#117 TUBING: The garment tubing is manufactured by the Freelin-Wade Co. and is produced in pleural form consist- ing of two groups of 4 Tubes bonded together and color coded with 3 tubes in blue and 1 tube in black. This color coding prevents attachment of both tubing bundles to the pump is reverse order.
  • Page 10: Warranty Information

    Compression Pumps = 3 years from date of purchase / invoice Sleeves/Garments = 1 year from date of purchase / invoice REPAIR SERVICE 1-800-888-0908 BIO COMPRESSION SYSTEMS, INC. 120 West Commercial Ave., Moonachie, NJ 07074 www.biocompression.com NOTES:_____________________________________________ Serial Number:_______________________________________...
  • Page 11: Cleaning Instructions

    CLEANING INSTRUCTIONS Exterior Case Cleaning Instructions: Clean the exterior case and tubing with a damp (not wet) cloth using a mild soap and water solu- tion once per month or as needed. Do not allow liquids to enter the equipment, an electrical haz- ard may be presented.
  • Page 12 BIO COMPRESSION SYSTEMS 120 West Commercial Avenue Moonachie, New Jersey 07074 Phone: 800-888-0908 Fax: 201-939-4503 Web site: www.biocompression.com E-mail: biosystems@biocompression.com Manual –2004/3004 – Rev. 01-14-10-D...