PRESSING DOUGH:
First allow the upper platen to reach
programmed temperature. In most
cases, 150°F (65.5°C) is ideal, but trial
and error testing will determine the best
temperature for your dough.
For best results, your dough should be
proofed before pressing, but it will also
press directly out of your refrigerator.
Flour is not required to press a crust
and should not be dusted on any part of
the machine.
Determining the proper timer setting
also requires some trial and error until
you obtain the correction thickness and
diameter of your product. Start with five
(5) seconds and go up or down from
there. Remember that the timer does
not actuate until the upper platen mates
with the lower platen and resistance is
felt.
1. Apply a quick spray of a good
water based food release on the
lower platen. Doughpro offers
its own food release spray
NATURALLY CLEAR Model
No. DPPC1. (See our catalog
and price list for information.)
Note: This spray will not affect
the taste of your crust in any
way.
2. Place your pre-portioned ball of
dough in the approximate center
of the lower platen. Add another
dash of spray to the top of the
dough ball.
3. Close the platen and, with both
hands, press the two green
buttons on the face of the press.
4. Hold the buttons in until
resistance is felt then release at
once. The timer will actuate and
when the time cycle is
completed, the upper platen will
rise automatically (timer is preset
at factory for six (6) seconds, but
this is easily changed by
following the upcoming
instructions.)
5. Remove the crust, place on disc,
screen, pan or peel, add toppings
and bake.

ADDITIONAL NOTES:

Temperature
Note
Fahrenheit/Centigrade (Celsius)
Conversion
The temperature controller can
be programmed to display either
°F or °C. To change: Press the
MODE button until the
temperature is displayed, then
push and hold the SET button for
10 seconds.
Timer
• The controller has a count down
timer that automatically activates
a buzzer at the completion of the
application.
• Timer display is minutes:
seconds. Range is 00:00 to
10:00; Colons (:) flash while
timer is running.
-4-
DP3300 1410/20003/40002 5/03