Symptom
Power Button on Digital Controller
face is depressed but doesn't turn
on.
Digital Controller's LED's are
scrambled or randomly irratic. If
when turning on, the display will
first go to segment check
Digital Controller on startup goes
through LED segment check (8888)
then to version # and then loops
back to to the above reboot.
Digital display shows PROB. No
heat on Upper Platen.
When depressing the tactile button
on Digital Controller, nothing
happens.
Digital display shows Relay and
Particular zone is over heating or
outer zone).
Beeper not functioning or
intermitten beeper sound.
DOUGHPRO
DP3300 Trouble Shooting Guide
Probable Cause
Power Cord is not plugged in.
Circuit Breaker is tripped off in the
site's breaker box
Transformer has taken a electrical
surge and is damaged
Check voltage on the secondary side
of the Transformer. If you read
12VDC then you are receiving voltage
to the Controller.
Possibly blown Fuse
Possibly a componet on the Digital
Controller is damaged
Possibly control needs to reset
The relay driver on the digital control
may be blown.
Sensor lost it's continuity as shown
on a muti-meter.
The tactile buttons under the overlay
may be not close enough to activate.
Same goes if the buttons are already
pressed by overlay without
depressing button.
The Relay on the switched side is not
opening to regulate temperture.
Beeper on Digital Control board
failed.
Action to be Taken
Plug power cord into wall 's
receptacle and depress power
button on controller
Reset circuit breaker that the Grill is
plugged into. Depress Power Button
to turn on.
Replace Transformer after you check
secondary side of transformer. If
working properly, you should
receive 12vdc.
Replace Controller. Controller
should be on once the power button
is depressed.
Replace fuse.
Replace Digital Controller
While unit is on (controller lit up)
Unplug unit, wait for 1 min. then
plug machine on and depress power
button.
Replace Digital Controller.
Disconnect prob that is open (no
continuity as shown on a multi-
meter. Must replace Sensor (RTD).
Do not cut and splice new sensor.
Install new 2000 ohm RTD sensor to
under side of Heat Platen and
reconnect to Controller.
Carefully (no too much at one time
to avoid fracturing the traces on the
Controller) tighten the nuts on the
back of the Controller until button
activate. Same goes in reverse if
buttons are held down by the
overlay.
Replace the Relay.
Replace Digital Controller board
Ref. #'s on
Explosion
Drawing
68
___
91
85
105
85
___
85
41
___
92
85