Connecting the Mitel GX Gateway Using a Static IP Address

Before you start
Your network interface must be set with an IP address in the 192.168.0.0/24 subnet (e.g.
192.168.0.11).
You must use an IPv4 Network.
Make sure that your network connection is working.
Steps
1)
Make sure an adequate earth ground connection has been made between the grounding
screw on the back of the Mitel GX Gateway and an appropriate grounding point in your
Warning:
damage or injuries.
2)
Wear an ESD wrist strap, ensuring it makes good contact with your bare skin.
3)
Attach the ESD wrist strap end to an earth ground (grounding screw on the back on the Mitel
GX Gateway or unpainted bare metal spot of a grounded equipment rack).
4)
Make sure the unit's power switch is OFF.
5)
Make sure the circuit breakers of power sources used to power the Mitel GX Gateway are OFF.
6)
Make sure the provided AC Power Cord is connected into the POWER connector located on
the back of the Mitel GX Gateway and in an appropriate AC electrical outlet.
7)
Connect a 10/100/1000 BaseT Ethernet RJ-45 cable into the ETH5/EXT Ethernet connector of
the Mitel GX Gateway.
8)
Connect the other end of the cable into your PC.
9)
Validate the installation.
10)
Turn ON the power sources that are used to power the Mitel GX Gateway at the circuit breaker.
When the unit is brought from a cold to a warm environment, condensation, that might
Note:
be harmful to the unit, may occur. If this is the case, wait one hour before connecting the
power cord.
11)
Turn On the power switch of the unit.
Result
You can now use the 192.168.0.10 IP address to access your unit's management interface.
GX Gateway Hardware Installation Guide
Adequate earth grounding connection of the Mitel GX Gateway is mandatory to avoid any
21
site.