Requirements; Location Requirements - Mitel Mediatrix Model M Hardware Installation Manual

Gx gateway
Table of Contents

Advertisement

Requirements

Location Requirements

To avoid premature aging of the unit, ensure user security and facilitate access, upgrades and maintenance, the
following guidelines must be followed.
Install the Mitel GX Gateway:
on a standard 48.26 cm (19 in.) equipment rack
on a flat surface (desk, table, etc.)
Install the Mitel GX Gateway in a well-ventilated location where it will not be exposed to high
temperatures or humidity.
Storage temperature: -
ºC to +70ºC
Operating temperature: 0ºC to +40ºC
Caution:
temperature of the environment next to the Mitel unit may become greater than the
maximum operating temperature recommended by Mitel for the use of its units, i.e. 40ºC.
The Mitel GX Gateway should never be used to temperatures greater than the
recommended maximum operating temperature. Any damage occurring in such
environmental conditions will void the warranty.
Humidity lower than 85% and non-condensing
Do not install the Mitel GX Gateway in a location exposed to direct sunlight or near stoves or
radiators. Excessive heat could damage the internal components.
Unit should be positioned to be accessible for future upgrade, maintenance and
troubleshooting and where cables can be easily connected.
Maintain a minimum of 25 mm (1 in.) clearance in front, in the back, on top, under (for rack
mounted units), and on the sides of the unit.
Keep airflow around and through the vents of the unit clear of any obstruction.
Do not put books or paper on the unit.
GX Gateway Hardware Installation Guide
If the unit is installed in a closed environment or on a multi-unit rack, the ambient
10