Troubleshooting; Led Patterns - Mitel Mediatrix Model M Hardware Installation Manual

Gx gateway
Table of Contents

Advertisement

Troubleshooting

Problem
Unable to contact the Management Interface.
Card does not appear in the Management
Interface.
Card appears in the Management interface, but
cannot be used (For example, unable to make
calls).
Unable to contact the Management Interface via
the CLI.
Unable to contact the unit via SNMP.
Unable to make calls, although cards appear in
the Management Interface.

LED Patterns

LED state
All LEDs cycling from left to right, individually
blinking 1 cycle per second, 33% duty.
All LEDs blinking at 3 cycles per second, 50%
duty. One LED out of two has a 180 degree
phase. This pattern lasts for 8 seconds.
Power1 or 2 and Ready LEDs blinking
(synchronized) 1 cycle per second, 75% duty.
Power LED blinking, 1 cycle per 4 seconds, 75%
duty.
GX Gateway Hardware Installation Guide
Description
A firmware pack is being downloaded into the unit
and written to persistent storage.
The download of the firmware has failed. After 4
seconds, the unit restarts.
The partial reset is completed.
Triggered when the unit is booting on the recovery
bank and no update is pending.
Cause
Wrong Eth port used for the Network configuration
(Mitel GX Gateway on the edge or in the LAN with
or without a DHCP server).
The card is broken.
The unit is broken.
The card is not configured properly. Refer to the
Software Configuration Guide.
CLI service not activated in the configuration.
Protocol used to contact the CLI not activated.
SNMP service not activated.
Credentials do not grant access.
Hour and date are not synchronized (required by
certificates).