Mitel AG4100 Analog Gateways 04/2024 QUICK INSTALLATION GUIDE...
Page 2
Mitel or any of its affiliates or subsidiaries. Mitel and its affiliates and subsidiaries assume no responsibility for any errors or omissions in this document. This document may be reviewed or re-edited at any time in order to add new information.
ABOUT THE MITEL AG4100 ANALOG GATEWAYS ..............4 GENERAL GUIDELINES ....................... 4 LOCATION GUIDELINES ......................4 WIRING GUIDELINES ........................5 PRESENTATION OF THE MITEL AG4100 ANALOG GATEWAYS ............6 MITEL AG4124 ANALOG GATEWAY ................... 6 2.1.1 MITEL AG4124 FEATURES ..................... 6 2.1.2...
The Mitel AG4172 is available for the MiVoice Business and the MiVoice 5000 products only. GENERAL GUIDELINES To ensure that the Mitel AG4100 Analog Gateways works well, adhere to the following guidelines: Follow the safety recommendations. refer to the document Mitel AG4100 Series •...
• For the Mitel AG4124 hardware maintenance, unplug the RJ11 (Front) and RJ21 (Rear) cables of the Mitel AG4124 at first. Unplug the Mitel AG4124 power supply from the mains power next. For the Mitel AG4172 hardware maintenance, unplug the RJ21 (Rear) cables of the •...
Height: 4,4 cm (1 ¾”) • Weight 3,2 kg (7lbs) • 2.1.3 MITEL AG4124 LIMITATIONS Up to 12 lines out of the 24 lines supported by the Mitel AG4124 can ring or light MWI lights • at the same time. 04/2024...
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE 2.1.4 MITEL AG4124 PORT TYPES AND PLUGS Front panel 24 RJ11 FXS analog ports, from 0 to 23 IEC-950 receptacle for the power cable Grounding lug RJ48 RS232 Console port Rear panel...
Height: 4,4 cm (1 ¾”) • Weight 4,25 kg (9,4lbs) • 2.2.3 MITEL AG4172 LIMITATIONS Up to 36 lines out of the 72 lines supported by the Mitel AG4172 can ring or light MWI lights • at the same time. 04/2024...
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE 2.2.4 MITEL AG4172 PORT TYPES AND PLUGS 1 RJ48 RS232 Console port 2 RJ45 10/100Mb/s LAN ports Front panel 1 RJ45 10/100Mb/s Management port 1 AUX port IEC-950 receptacle for the power cable...
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE 2.2.5 MITEL AG4172 INDICATORS Indicator Definition Status Description The Mitel AG4172 Analog Gateway Shows if the is on. Mitel AG4172 The Mitel AG4172 Analog Gateway Analog Gateway is is off, or the power supply is...
REQUIRED TOOLS AND EQUIPMENT Tools Phillips #2 screwdriver for the rack mount brackets. • • Anti-static wrist strap to protect the Mitel AG4124 or AG4172 Analog Gateway from electrostatic discharges (ESD). Equipment For the Mitel AG4124 Analog Gateway: • RJ11 and RJ21 cables to connect the analog terminals.
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE CHECK LIST OF THE INSTALLATION PROCESS Task Done by Date Identify a suitable location to install the Analog Gateway guidelines. Refer to the section 1.3 – Location guidelines. Ensure that the required equipment and tools for the installation are available.
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE HARDWARE INSTALLATION REMINDER: The Mitel AG4172 is available for the MiVoice Business and the MiVoice 5000 only. PRELIMINARY OPERATIONS Write down or take a photo of the serial number of the Analog Gateway. The label with the •...
Connect the terminals to the Analog Gateway. • For the Mitel AG4124 Analog Gateway: There are two options for connecting up to 24 terminals to the AG 4124: The terminals may be connected to the RJ11 connectors located on the front panel of the Mitel AG4124.
SOFTWARE INSTALLATION AND CONFIGURATION REMINDER: The Mitel AG4172 is available for the MiVoice Business and the MiVoice 5000 only. MIVOICE 5000 Refer to the document Mitel EX Controller, Mitel GX Gateway, Mitel AG4124 and TA7100 – Installation configuration available Mitel...
APPENDIX RJ21 CABLE 6.1.1 RJ21 CABLE RECOMMENDATON The RJ21 cable reference to use with the Mitel AG4100 gateways is 25 Pair Telco Cable with 180 Degree, 50-Pin RJ21, Male, Bail Lock, Amphenol Connector. 6.1.2 RJ21 WIRE SEQUENCE The recommended RJ21 cable has 25 pairs of wires but the Analog Gateways only supports 24 pairs, from Pair 0 to Pair 23.
MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE 6.1.3 LONG LINE SUPPORT CONFIGURATION The Mitel AG4100 Analog Gateways supports long lines, for loops longer than 800 meters. To enable this option: • Access the Analog Gateway Web Admin with a browser.