(2) Logic/Pulse Settings
Device Number: Specify which of the connected devices to use for logic input.
Logic: Off, On
Select On if a Device Number was specified.
• Line Color: Specifies the colors for channels 1 to 4.
Pulse
• Line Color:
Specifies the color.
• Input:
OFF, Counts, Revolutions, Inst.
OFF: Pulses are not measured.
• Revolutions: Counts the number of pulses at 1-second intervals and converts them to
revolutions.
• Counts:
Displays the cumulative number of pulses for each sampling interval from the
start of measurement.
• Inst.:
Counts the number of pulses for each sampling interval.
Range: Can be set for each of the modes.
Mode
Revolutions
Counts
Inst.
Slope: Sets the condition for the input signal operation.
• H: Operates when the signal is a rising signal
• L: Operates when the signal is a falling signal.
Range
50k, 500k, 5M, 50M, 500M C/F.S.
500, 5k, 50k, 500k RPM/F.S.
50k, 500k, 5M, 50M C/F.S.
Maximum number of pulse inputs
50 k/sampling interval
50k/s
50 k/sampling interval
Software
4-15