CLEANING PROCEDURE-24 HOUR STORES
(WITHOUT LOWER RELEASE SHEETS)
1. Clean the grill using the daily cleaning procedures on
pages 60–66.
2. After the grill pad has cooled, remove, wash, and
rinse it thoroughly at the three-compartment sink.
Turn the grill pad over and reinstall it on the grill pad
holder.
3. Wash, rinse, and sanitize all utensils and tools used
to clean the grill at the three-compartment sink.
Figure-171
4. The grill is now ready to use.

QUARTERLY RECOVERY MODE PROCEDURES

(Follow the McD Grill Recovery Cleaning Procedure
from EcoLab)
Note: Use new and clean tools for recovery application.
Note: PPE (gloves, apron, and a face shield) should be
worn when following the cleaning procedure due to the
high temperature of the grill.
Important! : Remove the upper and lower release sheets
prior to Recovery procedure.
CAUTION! Do not remove the grill filters.
Cleaning without the filters can cause severe burns or
fire.
1. Ensure Recovery mode programming has been
completed on the grill before initiating cleaning.
2. Press the Recovery key
mode. See Figure-172.
to enter the Recovery
67
Figure-172
3. The Recovery mode is on. See Figure-173.
Figure-173
4. Press the STANDBY button to start the recovery
process. See Figure-174.
Figure-174
5. Select the Recovery setting
interface and allow the grill to cool before cleaning.
Do not turn the fan interlock off. Allow the grill to
reach 285F before cleaning. A temperature of 285F
is critical to maximize the effectiveness of the
cleaning product.