RF600 system planning
4.7 Chemical resistance of the transponders
Substance
Tested fuels
FAM testing fluid
acc. to DIN 51 604-A
Toluene
1, 1, 1-Trichloroethane
Xylene
Zinc chloride (saturated)
Explanation of the rating
○○○○
○○○
○○
-
4.7.8
Polyvinyl chloride (PVC)
Table 4- 12
Substance
Salt water
Sugared water
Acetic acid, w.
Sodium carbonate, w.
Ethyl alcohol, w.
Ethylene glycol
Fuel B
(acc. to ISO 1817)
Human sweat
Explanation of the rating
○○○○
○○○
○○
-
82
Resistant
Practically resistant
Conditionally resistant
Less resistant
Not resistant
Chemical resistance - polyvinyl chloride (PVC)
Resistant
Practically resistant
Conditionally resistant
Less resistant
Not resistant
Test conditions
Concentration [%]
Temperature [°C]
Test conditions
Concentration [%]
Temperature [°C]
5
10
5
5
60
50
System Manual, 10/2016, J31069-D0171-U001-A19-7618
Evaluation
80
○○○○
80
○○
80
○○○○
80
○○
75
○○○○
Evaluation
○○○○
○○○○
○○○○
○○○○
○○○○
○○○○
○○○○
○○○○