Product
Set of protective caps
Contains 3 protective caps for antenna output, one protec-
tive cap for digital I/O interface and 2 protective caps for
Ethernet/PROFINET (required for IP65 degree of protec-
tion when some connectors are unused)
DVD "Ident Systems Software & Documentation"
5.4.1.3
Pin assignment of the digital I/O interface
View of socket (reader end)
Table 5- 22
M12 socket (reader end)
Note
Requirement for external power sources
When the digital I/O interface is supplied by an external power source, the power source
must meet the requirements for LPS (Limited Power Sources) and NEC Class 2.
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
Pin
Pin assignment
1
GND (output for supply of digital inputs/outputs [not electrical-
ly isolated])
2
VCC (output for supply of digital inputs/outputs [not electrically
isolated])
3
DO Common / Outport Common
4
DO 0 / Outport 00
5
DO 1 / Outport 01
6
DO 2 / Outport 02
7
DO 3 / Outport 03
8
DI 0 / Inport 00
9
DI Common / Inport Common
10
DI 1 / Inport 01
11
DI 2 / Inport 02
12
DI 3 / Inport 03
5.4 RF685R reader
Article number
6GT2898-4AA10
6GT2080-2AA20
Readers
145