Number of write cycles (< 40 °C)
Number of read cycles (< 40 °C)
Data retention time (< 40 °C)
Electrical data
Range
Protocol
Transmission speed
Polarization
Mechanical specifications
Material
Silicone-free
Color
Antenna material
Type of antenna
Imprint
Roll core diameter
Roll outer diameter
Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
7.6 SIMATIC RF690L Smartlabel
> 500
> 10
14
50 years
≤ 5 m
2)
EPCglobal Class 1 Gen 2 / ISO 18000-63
≤ 320 kbps
Linear
PET
Yes
Beige/silver
Aluminum
Shortened dipole
Can be printed using heat transfer technique
76 mm
200 mm
-25 to +85 °C
-25 to +95 °C permanently
Special features:
As of 100 °C 20 % reduction of the limit dis-
tance
+140 ... + 160 °C: No processing possible
+13 ... +23 °C
3)
Suitable for direct attachment to metal
IP67
Torsion and bending stress conditionally permis-
sible
Transponder
6GT2810-2AGx0