  • Page 1 022-0821 02205284 *02205284* ® User Guide Original User Guide ENGLISH...
  • Page 2: Table Of Contents

    ROXELL - 022 - 1020 - USER'S GUIDE - EUG Swii'Flo  TABLE OF CONTENTS TABLE OF CONTENTS DISCLAIMER GENERAL INFORMATION WATER QUALITY ............. . .
  • Page 3 Subsequent changes to any manual made by any third party have not been reviewed nor authenticated by Roxell. Such changes may include, but are not limited to, translation into languages other than English, and additions to or deletions from the original content. Roxell disclaims responsibility for any and all damages, injuries, warranty claims and/or any other claims associated with such changes, inasmuch as such changes result in content that is different from the authoritat- ive Roxell- -published English version of the manual.
  • Page 4 Roxell’s most current use and maintenance manuals; use of cleansing agents and disinfectants in violation with the instructions received from the suppliers;...
  • Page 5 In the European Union If you have used the product for commercial purposes and you want to dispose of it, contact Roxell, who will give you information about the return of the product. It is possible that you will have to pay a disposal charge for the return and recycling.
  • Page 6 Roxell – – 0821 – General information LOTOTO = Lock Out - Tag Out - Try Out Before you begin: Everyone needs his own lock and tag (label), which can’t be removed by other persons. Inform all the persons who are influenced by the procedure.
  • Page 7 – General information Roxell – – 0821 Information about the residual risks - used safety signs There are three levels of danger, which you can recognize from the following signal words: • DANGER • WARNING CAUTION • The nature and source of the imminent danger and possible consequences of not obeying warnings is stated here!
  • Page 8: Water Quality

    - USER'S GUIDE - EUG ROXELL - 022 - 1020 Swii'Flo  WATER QUALITY Warning The health of the animals depends on the quality of their daily drinking water. The water quality depends on:  The phosphate, nitride, nitrite, chloride, iron, calcium and other concentrations.
  • Page 9 ROXELL - 022 - 1020 - USER'S GUIDE - EUG Swii'Flo  Iron: When water is pumped to the surface, iron occurs in its soluble ferrous form. The insoluble ferrous ions oxidize upon exposure to air or dissolved oxygen. These and other chemical reactions cause insoluble gelatinous deposits.
  • Page 10: General Safety Rules Handwinch

    3. DON'T wear loose clothing. 4. Only adults may handle the hand winch. 5. Only use the hand winch for suspension of a ROXELL drinking line. 6. Only use the hand winch with the supplied handle. 7. ALWAYS check the condition of the hand winch and the cable before operating.
  • Page 11: Minimum Pressure And Flow

    Swii’Flo- - USER'S GUIDE - - EUG 2.2. MINIMUM PRESSURE AND FLOW Max. ingoing pressure is 9 bar! WARNING Pressure range: Roxell Water panel & pump suitable for: Water tank Pump Regular operation:  0,4 Bar 2 - 3 Bar...
  • Page 12: Water Panel

    3. WATER PANEL Non return valve 1” Pressure restrictor Ball valve Bypass valve Key for filter Filter Medicator FIGURE 2.
  • Page 13: Filter Cleaning, When, How

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 3.1. FILTER CLEANING, WHEN, HOW? General rule: when the difference between the inlet and outlet gauges > 0.5 bar! CLEANING FIGURE 3. FIGURE 4. TO CLEAN THE FILTER:...
  • Page 14 ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG REGULAR CLEANING: Clean with water. FIGURE 6.
  • Page 15 ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG OR: INTENSIVE CLEANING: See topic 2.1 Cleaning and disinfection. FIGURE 7.
  • Page 16: Operation Of The Valves

    3.2. OPERATION OF THE VALVES NORMAL OPERATION 1” 1” 1” 1” 3/4” 3/4” 3/4” FIGURE 8.
  • Page 17: Operation With Medicator

    OPERATION WITH MEDICATOR 1” 1” 1” 1” 3/4” 3/4” 3/4” 3/4” 3/4” FIGURE 9.
  • Page 18: To Check And To Clean The Medicator

    TO CHECK AND TO CLEAN THE MEDICATOR 1” 1” 1” 3/4” 3/4” 3/4” 3/4” 3/4” FIGURE 10.
  • Page 19: Divided Houses - Normal Operation

    DIVIDED HOUSES - NORMAL OPERATION 1” 1” 1” 1” 1” 3/4” 3/4” FIGURE 11.
  • Page 20: Divided Houses - Option: Medication

    DIVIDED HOUSES - OPTION: MEDICATION 1” 1” 1” 1” 3/4” 3/4” 1” FIGURE 12.
  • Page 21: To Adjust The Line Height

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 4. TO ADJUST THE LINE HEIGHT 4.1. TO ADJUST HEIGHT OF COMPLETE LINE (  1M) FIGURE 13. > 1 week > 1 week 2- -7 days 75 ...
  • Page 22: To Adjust Line With 3 Hole String Adjuster

    ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG 4.2. TO ADJUST LINE WITH 3 HOLE STRING ADJUSTER FIGURE 15. FIGURE 16. 4.3. TO ADJUST LINE WITH THE SUSPENSION SCREW FIGURE 17.
  • Page 23: Operation Of The System

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 5. OPERATION OF THE SYSTEM 5.1. MODE OF THE PRESSURE REGULATOR NORMAL- OPERATION CLOSED FLUSHING FIGURE 18. 5.2. TO REGULATE THE PRESSURE FIGURE 19.
  • Page 24 ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG 7-12 cm 0- -7 days: FIGURE 20. 15-20 cm 7- -21 days: FIGURE 21. 25-30 cm 21 days - - end of the flock: FIGURE 22.
  • Page 25: To Use The End Unit

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 5.3. TO USE THE END UNIT OPERATION MODE FLUSHING MODE FIGURE 23. 5.4. TO USE THE INTERMEDIATE SHUT OFF VALVE Situation: The whole house FIGURE 24. Situation: Partial brooding...
  • Page 26: Flow Of Nipples

    ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG 5.5. FLOW OF NIPPLES Pressure measured from top op the hose pillar of the pressure regulator. VT 80 Lubing Side Action Water column (cm) FIGURE 26. VT 130...
  • Page 27 ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG FS 80 Vertical Lubing Side Action Water column (cm) FIGURE 28. FS 130 Vertical Lubing Side Action Water column (cm) FIGURE 29.
  • Page 28: To Clean The System

    ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG 6. TO CLEAN THE SYSTEM In order to maintain the correct functioning of the drinking system, cleaning (flushing) should be performed on a regular basis. 6.1. MANUAL FLUSHING Flushing time: sec.
  • Page 29: Flushing Using The Overflow

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 6.2. FLUSHING USING THE OVERFLOW CAUTION Flushing time: sec. / line = # tubes / line x 6 sec. Example: 90 m = 30 tubes x 6 sec. = 180 sec.
  • Page 30: Automatic Flushing (Operation Explained In Controller Manual)

    ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG 6.3. AUTOMATIC FLUSHING (OPERATION EXPLAINED IN CONTROLLER MANU- CAUTION FIGURE 32.
  • Page 31: To Administer Vaccine Or Medication

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 7. TO ADMINISTER VACCINE OR MEDICATION HOW TO DO Note: Follow the instructions of the additive supplier ! CAUTION FIGURE 33. Check function of medicator. FIGURE 34.
  • Page 32 ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG To administer the additives. Check that the additive has reached the end of the line. FIGURE 35. ALWAYS clean the system before and after administering! CAUTION...
  • Page 33: Perch Protection And The System

    ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG 8. PERCH PROTECTION AND THE SYSTEM 8.1. ELECTRICAL PERCH PROTECTION When entering the house, FIRST switch off the electrical power! The line height should be correct depending on the age of the birds.
  • Page 34: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS Switch off the main switch first. Use personal protective equipment. DANGER ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON. At first system startup During the flock Between 2 flocks Every 6 months Check differential pressure and Check differential pressure daily Clean filter cartridge quickly as Clean filter cartridge carefully as...
  • Page 35: Trouble Shooting Guide

    Water is too hot. Rinse every hour with fresh, cool water. You can use the RFC (Roxell Flushing Controller) to do this automatically. c. Nipple is not suitable for the type of Consult the recommendations types of bird-nipple.
  • Page 36 ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG PROBLEM CAUSE CORRECTIVE ACTION h. Debeaked birds. Install start cups. i. Not enough water consumption by - Increase pressure. - Increase lighting. day-olds. j. Too many birds per nipple.
  • Page 37 ROXELL - -022 - - 2313 Swii’Flo- - USER'S GUIDE - - EUG PROBLEM CAUSE CORRECTIVE ACTION 11. Perching animals in a. Spinners touch the suspension - Check if clearance between hangers and wings is sufficient according to the instruc- case of SpinSoft tube.
  • Page 38: House Chart

    02205508 1020 House chart Line height Operation of the drinking system Adjust the line height: General guidelines for the water pressure (water column) in > 1 week function of the age of the birds:: The line height depends on the size of the birds and their >...
  • Page 39 1020 02205508 House chart Manual flushing Flushing with overflow 1. Connect the end unit to the drain hose. Proceed as described in Manual Flushing. 2. Put the end unit valve in the flushing position. The end unit is connected to the drain pipe (overflow). 1.
  • Page 40: Hand Winch: Trouble Shooting Guide - Maintenance

    ROXELL - -022 - - 2313 Swii’Flo- - USER’S GUIDE - - EUG HAND WINCH TROUBLE SHOOTING GUIDE Not respecting above-mentioned instructions can cause physical injury or material damage. Use personal protective equipment. DANGER ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
  • Page 41: Declaration Of Incorporation Of Partly Completed Machinery

    Fabrikant/Manufacturer: Roxell bv, Industrielaan 13, 9990 Maldegem Tel: +32 50 72 91 72 “This part may only be filled out if all built-in subparts are delivered by Roxell” Fax: +32 50 71 67 21 EG-verklaring van overeenstemming (Richtlijn 2006/42/EG, Bijlage II.1.A)
  • Page 42: Ec-Declaration Of Conformity

    EG-verklaring van overeenstemming (Richtlijn 2006/42/EG, Bijlage II.1.A) EC-declaration of conformity (Directive 2006/42/EC, Annex II.1.A) Fabrikant/Manufacturer: Roxell bv, Industrielaan 13, 9990 Maldegem Tel: +32 50 72 91 72 Fax: +32 50 71 67 21 Verklaart geheel onder eigen verantwoordelijkheid dat het product:...
  • Page 44 ROXELL bv ‐ Industrielaan 13, 9990 Maldegem (Belgium)  Tel. +32 50 72 91 72 ‐ info@roxell.com ‐ www.roxell.com  ROXELL USA Inc. ‐  720 Industrial Park Road, Anderson MO 64831 (USA)  Tel. +1 417 845 6065 ‐ info.usa@roxell.com ‐ www.roxell.com  ROXELL Malaysia ‐ No. 49, Jalan Permata 2/KS9, Taman Perindustrian Air Hitam, 41200 Klang, Selangor (Malaysia)  Tel. +60 3 3123 1767 ‐ info.malaysia@roxell.com ‐ www.roxell.com  ROXELL Россия ‐ ООО «Рокселл» ОГРН 1157746055026  125167, Россия, город Москва, Ленинградский проспект, дом 37, корпус 9, помещение 653  Телефон: +7 495 983 30 15 ‐ Адрес электронной почты: info.russia@roxell.com ‐ www.roxell.com ...