1.6.2
II 2G allowable temperature TG MAG
ISO EN 80076-36
Temperature class
T
max
T4 - 135°C
T3 - 200°C
T2 - 300°C
T1 - 450°C
(*) temperature to decrease according to material limits (see IM).
(**) special bearing construction required, please contact SPX or your local distributor
When the temperature limits are reduced because of internal materials selection, the
maximum allowable surface temperature T
temperature class, the same way as in case of D, dust protection.
For T5 (100°C) and T6 (85°C) classes and if ambient temperature exceeds the range
-20°C / +40°C contact your distributor.
1.6.3
II 2(G)D allowable temperature TG GS, GP, GM, H and SRT
The maximum surface temperature (T
T
is determined as the lowest temperature derived from following equations:
max
• T
= temperature limits of selected internal materials (i.e. pump selection).
max
• T
= T
max
• T
= 2/3 x T.
max
Remark:
T
and T
5mm
In case the ambient temperature exceeds the range of -20°C / +40°C contact your
distributor.
Maximum surface
temperature
T
max
135°C
170°C
200°C
220°C
240°C
260°C
280°C
300°C
330°C
*) corresponding temperature class of Gas protection indicated on the nameplate between brackets
TG GS, GP, GM, can be used in a temperature range between -20ºC and +40ºC.
TG H in stainless steel execution can be used in a temperature range between -40ºC
and +40ºC; materials other than stainless steel can be used in the temperature range
between -20ºC and +40ºC.
8
Pumped medium
temperature T
A
≤ 100°C
≤ 160°C
≤ 250°C *)
≤ 260°C *)
- 75°C (T
"ignition temperature of a dust layer of 5 mm thickness")
5mm
5mm
(T
"ignition temperature of a dust cloud").
CI
CI
are to be determined by the customer/user in case of dust (D) protection.
CI
Heating medium T
Pumped medium
temperature T
A
T.class *)
S-jacket
(T4)
≤ 120°C
≤ 120°C
(T3)
≤ 150°C
≤ 150°C
(T3)
≤ 180°C
≤ 180°C
(T2)
≤ 200°C
(T2)
≤ 220°C
(T2)
≤ 235°C
(T2)
≤ 250°C
(T2)
≤ 270°C
(T1)
≤ 300°C
Heating medium T
(if any)
A
S-jacket
T-jacket
≤ 100°C
≤ 100°C
≤ 160°C
≤ 160°C
≤ 250°C *)
≤ 260°C *)
will be supplied instead of the
max
) is indicated on the name plate.
max
(if any)
Bearing bracket
A
temperature (L3)
T-jacket
≤ 120°C
≤ 100°C
≤ 150°C
≤ 120°C
≤ 180°C
≤ 120°C
≤ 200°C
≤ 160°C
≤ 220°C
≤ 160°C
≤ 235°C
≤ 160°C
≤ 250°C
≤ 160°C
≤ 270°C
≤ 180°C
≤ 300°C
≤ 180°C
A.0500.601 – Atex IM -TG G/H/MAG/SRT/08.00 EN (01/2021)
Separation can
Bearing bracket
temperature (L2)
temperature (L3)
≤ 120°C
≤ 100°C
≤ 180°C
≤ 100°C
≤ 270°C
≤ 160°C **)
≤ 280°C
≤ 160°C **)