Analyser Calibration; Maintenance And Cleaning; Servicing - Abbott SoToxa Oral Fluid User Manual

Mobile analyser
Hide thumbs Also See for SoToxa Oral Fluid:
Table of Contents

Advertisement

1 . I N T R O D U C T I O N
• Please ensure that the mains supply cable for the power supply unit is appropriately rated and approved as per the applicable
national requirements.
• As with any electrical instrument or equipment, care is required when handling the analyser to ensure that it is not subjected to heavy shocks or
dropped from any height. Never exert undue force on the surface of the display, or expose any part of the analyser to sharp or abrasive objects.
• Use the analyser indoors when connected to AC power.
• Do not open the analyser. The analyser contains no user serviceable parts. Any unauthorized opening of the analyser can cause hazards and
will invalidate warranty claims.
• It is highly recommended that all PCs supporting the Software Application Suite (if used) carry up-to-date antivirus software.
• The test cartridges are designed for single use only – do not attempt to re-insert a used test cartridge into the analyser.
• Do not insert fingers or objects other than the test cartridge into the test cartridge slot. This may result in harm to the user or damage to
the analyser.
• Do not use dirty or damaged test/QC cartridges as this may damage the analyser or cause an invalid test result.
• Do not use the analyser or any of its electrical accessories if these appear to be damaged. Contact Customer Service to arrange for
replacement parts.
• Do not use the analyser near a magnetic source.
• Do not ingest the silica gel packs.
• Do not open power supply casing or printer.
• Allow the analyser to reach ambient temperature before use. If moving the analyser between storage and operating environments of
different temperatures or humidities, this may take at least 30 minutes. If climatic differences are significant, allow more than 30 minutes for
the analyser to acclimatise.
• It is the responsibility of the user to ensure the date and time settings are correct.
1.9

Analyser calibration

The SoToxa™ Mobile Analyser is factory calibrated and does not require any further calibration by the user.
However, it is recommended to carry out a regular performance check using the quality control test cartridges provided with the SoToxa™
Mobile Test System (see section 7 QC Tests).
1.10

Maintenance and cleaning

If required, the exterior of the SoToxa™ Mobile Analyser and its accessories can be wiped with a lint free cloth or a damp cloth with mild
detergent. Wipe away any spillages immediately. Do not use abrasive cloths or other material, and do not allow the unit to come into contact with
any potentially corrosive substances. If using a damp cloth, ensure the analyser is turned off and disconnected from mains A/C power.
DO NOT try to clean inside the analyser or open the analyser for cleaning.
The analyser does not contain any user serviceable components. If a fault is suspected or routine factory maintenance is required, then please
contact Customer Service.
1.11

Servicing

The SoToxa™ Mobile Analyser requires an annual service which must be carried out by a qualified service engineer. It is important to
have your analyser serviced annually to ensure it is performing correctly. This requires the analyser and accessories to be returned to the
manufacturer or authorised servicing facility for a short period of time.
The date that the next service is next due can be viewed in the analyser summary screen, and the analyser will automatically display the
service symbol in the status line when service is due in less than one month. If the analyser is not returned to the manufacturer for servicing
within this time, the symbol will turn from white to orange.
Service status (OK, due or overdue) will be displayed in the test details for each test and will also be printed on test printouts.
Accuracy of tests carried out on an analyser which is overdue a service, may be reduced. Failure to return the analyser for annual service will
invalidate warranty claims.
6 | EN