Product Outline; Usage Of Product; Features Of Product; Composition Of Type - DAIICHI SFLC-110L Instruction Manual

Power line multi-meter
Table of Contents

Advertisement

1. Product outline

1.1 Usage of product

This single unit can measure and monitor voltage ×3, current ×3, demand-current ×3, active-power, demand
active power, reactive-power, power-factor, frequency, watt-hour, var-hour.
The measurement monitor of an initial power receiving circuit, an energy conservation power monitor, a demand
current measurement monitor, etc. are adapted for various usages from a low tension circuit to a high tension
circuit.
The intensive monitor doubled with the system by option (analog output, alarm output, pulse output,
external operation input) addendum is possible.

1.2 Features of product

 High-performance products which collected the function of the power line multi-meter (QLC-110L, DLC-110L)
of our company.
 It is common type product of 3-phase 3-wire, single-phase 2-wire, single-phase 3-wire.
It's possible to share stock.
 Bar graph 1 measurement and digital 4 measurement are displayed simultaneously.
 Analog output 3 circuit and a pulse output and a contact-output can be taken out. (Option)
And, An output factor can be selected by setting.
 External operation inputs are possible of reset. (Option) Choice of an alarm output, the maximum/minimum value,
and an alarm output, and the maximum/minimum value is possible at setting.
 Power supply is AC85~264V,DC80~143V (for both AC and DC uses).
 The mounting method of this unit is compatible with the mounting method of conventional 110 square
mechanical meter. This unit is mounted at 2 diagonal points.
 Integrated value of Wh and varh can indicate expansion to 3rd digit below the decimal point.
 A tidal current measurement (output 2 quadrant) change is possible for var and cosφ.
 A backlight function is equipped. Selection of backlight-on, backlight-off, and auto backlight-off and
setting of brightness (only white backlight) are possible.
of non-operation can be established. LED:Green or White (appoints by order).
 LCD can be chosen from 2 kinds, the type to see from the top and the type to see from the bottom.
(Please designate it at an order.)

1.3 Composition of type

TYPE
Specification code
SFLC-110L- □□□□□-□□□
Installation position
1:For an upper installation.
2:For an lower installation.
Option
Specification
External operation
code
0-00
Nothing
1-11
One circuit
1-M1
One circuit
1-A1
One circuit
Auxiliary power supply
1:AC85~264V, DC80~143V for both AC and DC uses
Input range
F:Common use for AC150V, AC300V. AC5A
Input circuit
F:Common use for 1φ2W, 1φ3W, 3φ3W.
Hardware model
A:R-S-T,Green backlight
B:R-Y-B,Green backlight
D:R-S-T,White backlight
E:R-Y-B,White backlight
8
Automatic turning off the lights at the time
Analog output or
input
communication output
Nothing
DC4~20mA×3 circuits
Modbus RTU (RS-485)
Protocol A (RS-485)
SFLC-211-185
Contact output
Nothing
Pulse + Alarm
Pulse + Alarm
Pulse + Alarm

Advertisement

Table of Contents
loading

Table of Contents