Maintenance; Storage; Countermeasures Against Troubles - DAIICHI SFLC-110L Instruction Manual

Power line multi-meter
Table of Contents

Advertisement

(5) LCD display check
It can check a liquid crystal display.
Default:Main monitor "LCD" display

7.4 Maintenance

(1) Please do not make a wiring change of the input and auxiliary supply in an energization.
(2) In case you check an output in an energization, please warn to be unable to touch output wiring and a
human body to an input and an auxiliary supply terminal. (Please do not short-circuit a voltage output.)
(3) Please check a connection diagram, in case you check the voltage of input, output, and auxiliary supply.
(4) If a name-plate is wiped with solvents (an alcoholic nature), a display item may disappear.
Please wipe off with the dry cloth.

7.5 Storage

(1) Please avoid storage in the next space. Low temperature, high temperature, high humidity, and sunny place.
(2) The aluminum electrolytic capacitor is used for a product. Please do the energization of the power supply
within one year after shipment.

7.6 Countermeasures against troubles

As our principle, we recall product in question and repair it. If judged as product failure, have a contact with
us or sales agent for repairing work (Also have a contact with us or sales agent for specification change).
Product failure which we are not responsible for (When responsibility in manufacturing process is not recognized,
when product is disassembled/remodeled, in case of false operation by customer, etc.) is beyond our warranty.
Whenever it pushes SET , a display changes.
SET
63
SFLC-211-185