HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Applications The 500774 is an ideal solution for HDMI/IP hybrid environments. It allows broadcasters the ability to have a single IP infrastructure rather than two different ones. The 500774 applications include commercial broadcast AV systems, news/sports/TV stations and movie networks.
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Specifications The following are the 500774 specifications. Environment HDMI 1.4 Devices Cameras, mixers, media players, monitors, TV, PC, laptops, servers supporting HDMI. Signals Up to HDMI 1.4 Connectors/Switches One (1) HDMI connector...
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Currently Supported Resolutions The following are the currently 500774 supported Video resolutions. Color Color 1080p 1080i 720p Depth Space 8 bit YCbCr 444 YCbCr 422 10 bit YCbCr 444 YCbCr 422 Legends: V –...
DHCP. If no DHCP is available on your network, both the TX and RX will default to a static IP Address of 192.168.168.66 for the TX, and 192.168.168.67 for the RX. To be able to log in to the 500774 Web interface, your computer has to be in the same subnet.
Cancel will discard any changes. Force ST2110 to 4:2:2 Note: The 500774 Tx unit contains 422 Converter that converts RGB or YCbCr 4:4:4 to YCbCr 4:2:2 10 bit Video Format. In the Media Setting Page this option can be disabled.
2.1.4 Transmitter RS232 Page This page allows RS232 signals to be sent via the 500774-TX via the “Data to send in HEX” field. This signal is sent to the end equipment connected to the 500774-TX. The 500774-TX can also display any RS232 feedback received from the end equipment in the “Data feedback received in HEX”...
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual 2.1.5 Transmitter Settings Page This page allows the user to set various parameters of the 500774-TX. Figure 5: 500774-TX Settings Page Firmware Upgrade The 500774-TX comes with the firmware pre-installed, please check the MuxLab Web site to verify if a newer version is available.
Page 12
RS232 Settings The user may set the RS232 parameters of the 500774-TX, including the Baud Rate, Data Bits, Parity, and Number of Stop Bits, and then pressing on “Apply”. Pressing on “Reset” will return the unit to the default settings.
Once connected, the first screen is the System Info page, which displays general product information such as the model number, firmware and FPGA version, MAC and IP address, RS232 settings, etc., Figure 6: 500774-RX System Info Page 2.1.8 Receiver Media Page The Media Page contains both the video and audio settings.
Page 15
Factory Reset The user may perform a factory reset, by pressing on the “Reset” button. This will return the unit to the original MuxLab factory settings, and all user settings and data will be lost. Reboot The user may reboot the unit (equivalent to a power cycle), by pressing on the “Reboot”...
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual 500774 RestAPI In addition to the Web interface, the 500774 can also be managed through a RestAPI. This section describes the API commands supported on the 500774. It is intended for users with a programing background.
Page 17
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual "ip": "192.168.168.190", "reset": 0, "reboot": 0, "forceStream": 1, "isTx": 1, "mediaMode": "None" Enter [500774-TX IP Address]/api/video for “Video API” "fps": "60000/1001", "sessionID": "11-497371921", "depth": 10, "TTL": 32, "port": 48000, "sdp": "api/video/sdp", "intlce": 3, "width": 1920,...
Page 19
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Enter [500774-TX IP Address]/api/rs232 for “RS232 API” "data": "", "baudrate": 115200, "waitTime": 0, "isFeedback": 0, "stopbit": 1, "databit": 8, "parity": "none" Enter [500774-TX IP Address]/api/security for “Security API” "get_status": 0, "get_id": "", "set_key": ""...
Page 20
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Enter [500774-TX IP Address]/api/others for “Other (remaining) API” "debugCmd": 1, "debugRest": 1, "debugSdp": 1, "authen": 1, "sdpc": [ "SDP Client is not available on TX" "threads": [ "name": "muxMain", "PID": 338 "name": "muxTimer", "PID": 366...
Page 21
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual 500774-RX RestAPI: The following screen shots show the RestAPI for the 500774-RX (Receiver): The RestAPI commands can be accessed directly from a browser by entering the 500774-RX IP Address and RestAPI command as follows:...
Page 22
HDMI 4K/ST2110 Over IP Uncompressed Gateway Operation Manual Enter [500774-RX IP Address]/api/video for “Video API” "port": 48000, "sdp": "api/video/sdp", "payloadType": 96, "depth": 10, "TTL": 32, "fps": "60000/1001", "sessionID": "11-1186003140", "colorSpace": "YCbCr-4:2:2", "intlce": 3, "ip": "239.100.1.1", "height": 1080, "width": 1920 Enter [500774-RX IP Address]/api/audio for “Audio API”...
500774. What is the default IP address of the 500774? By default the 500774 is configured in DHCP mode. If no DHCP server is available the unit will fall back to its default static IP address: 500774-TX IP Address: 192.168.168.66 / Subnet Mask: 255.255.255.0...
Page 27
The 500774-RX does not display video from another ST2110 manufacturer? Check media parameters and ensure you are entering the right SDP information if using this input type. If it is still not working, email the SDP file to MuxLab support. Need Further Help:...
(RMA#) issued by its Customer Service Department, along with a dated proof of purchase. If this product is delivered to MuxLab by mail, you agree to assume risk of loss or damage in transit, to prepay shipping charges to the warranty service location, and to use the original shipping container or equivalent.
Page 29
All R.M.A.’s issued are subject to inspection by MuxLab, and will be returned to the customer if not properly packaged – units must be returned in the original container or equivalent. MuxLab will not accept any such product for repair without an authorization from its Technical Support department and without a return authorization number issued by the MuxLab Customer Service department.
Need help?
Do you have a question about the 500774 and is the answer not in the manual?
Questions and answers