8.

Technical Data

8.1

Temperature and humidity

Designation
Operating Temperature
Storage Temperature
Relative operating humidity
8.2

KTS 350 (KTS 3a Series)

Property
Display
Operating system
Interfaces
Main-memory capacity
Hard disk
WLAN
Bluetooth

Power supply unit

Storage battery (Li-ion)
Dimensions (W x H x D)
Weight with storage battery,
without power supply unit
Type of protection
Maximum operating altitude
Voltage supply by vehicle via OBD
Caution: The diagnostic
connector of the vehicle must be
protected by a fuse with a max.
rating of 6 Amps / 32 Volt.
8.3

Bluetooth Class 1

Wireless link
Free field workshop environment
In passenger compartment, with
vehicle door or window open and
engine running
8.4

RED (Radio Equipment Directive)

Wireless link
Frequency band
Bluetooth
2,4 GHz
WLAN
5 GHz
Robert Bosch GmbH
Value / range
5 °C – 40 °C
41 °F – 104 °F
-20 °C – 60 °C
-4 °F – 140 °F
20 – 80 % non-
condensing
Value / range
10" TFT, WXGA
(1024 x 600 Pixel)
Windows 10 IoT (64-bit)
USB 3.0 (2x),
LAN 10/100 Mbit, VGA, Audio
4 GB DDR3 RAM
256 GB SSD
WLAN 802.11 b/g/n
Bluetooth 2.1, Class 1
12 V
7,4 V/ 5200 mAh
361 x 222 x 49 mm
14.2 x 8.7 x 1.9 inch
2,1 kg
4.6 lb
IP 20
2000 m
10 V – 28 V
Minimum range
30 m
10 m
Maximum radiated
transmitter power
output
<20 dBm (< 100 mW)
<20 dBm (< 100 mW)
Technical Data | KTS 350 (KTS 3a Series) | 25
8.5

Interface protocols

The following interfaces and their associated protocols
are supported for control unit diagnosis in compliance
with ISO 15031:
R
ISO 15031, ISO 22900
R
SAE J2534-1 and -2 (PassThru)
R
ISO 13400 (Diagnostic over IP)
R
ISO 9141-2 (communication lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(communication lines CAN-H and CAN-L)
R
CAN Single Wire, CAN Low Speed and additional
vehicle-specific special protocols
i
KTS 350 (KTS 3a Series) may be used for Euro
5-compatible vehicles with the PassThru Standard.
8.6
Power supply unit
Property
Input voltage (AC)
Frequency
Input current
Output voltage (DC)
Max. output current
en
Value / range
100 – 240 VAC
50 / 60 Hz
1.6 A
12 V
5.0 A
|
1 689 989 293