Battery
Danger:
The battery emits explosive gases. Keep away from any source of flame or
spark.
The battery contains sulfuric acid which can cause serious chemical burns.
Wear goggles and rubber/latex gloves to avoid any chemical contact with
skin.
If the acid comes into contact with skin or eyes, flush the area with plenty of
clean water and immediately seek medical assistance.
Battery Maintenance
Check terminals monthly.
Dielectric grease or petroleum jelly will prolong battery terminal life span.
When connecting the battery, connect the red lead (+) first, and then the
black lead (-). Reversing the leads will harm your machine.
Battery Charging
Keep the work area well ventilated
Disconnect the battery from the vehicle and remove it from the vehicle.
Use a charger that supplies 1.8A. 5-10 hours is sufficient.
The maximum charging rate is 9A for 1 hour.
Battery Status
Charge %
Voltage
100%
12.8-13V
75-100%
12.5-12.8V
50-75%
12.0-12.5V
25-50%
11.5-12.0V
0-25%
< 11.5V
Figure 29: Battery Location Under Hood
Action
None
May need charge
Needs charge
Needs charge
Requires charge from
desolating charger
44
Charge Time
None
3-6 hours
5-11 hours
12+ hours
See dealer