Troubleshooting; Schematics - Graco PD44 Operations & Parts List

Metering valve for high wear material
Hide thumbs Also See for PD44:
Table of Contents

Advertisement

Troubleshooting

Problem
Metering valve stalling and no mate-
rial being dispensed despite ade-
quate input pressure
Metering valve not discharging nor-
mal or full volume
Material leaks past spool valves
Improper material mixing
Material leaks around mixer while
dispensing

Schematics

For standard machines, see Electrical Requirements
on page 39 for wiring information.
For custom machines, the schematics will be included
in the assembly drawings manual.
3A7284B
1. Follow the Pressure Relief Procedure on page 19,
2. Check all possible problems and causes before
Cause
Blocked mixer
Flow control valve closed
Low material level in reservoirs
Air in material tanks
Spool valve worn or damaged
Mixer not clean or free
Cured material in mixer
before checking or repairing the PD44.
disassembling the metering valve.
Check mixer for cured material,
replace mixer as required
Open
Fill material reservoirs and prime the
machine
Fill reservoirs and prime machine
Replace the spool valve and sleeve
Remove and replace the mixer
Check mixer for cured material,
replace mixer
Troubleshooting
Solution
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ua0421

Table of Contents