3 TECHNICAL DATA
U
(with arc ignition unit, Tig)
pk
Operating temperature
Transportation temperature
Constant sound pressure in
open-circuit
Dimensions, l × b × h
Dimensions, l × b × h
(including cooling unit)
Weight
Shielding gas
max pressure
Insulation class transformer
Enclosure class
Application class
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
Enclosure class
The IP code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP23 is intended for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
Mains supply, Z
max
Maximum permissible line impedance of the network in accordance with IEC 61000-3-11.
0460 826 374
Tig 1500i
-10 to + 40 °C
(+14 to +104 °F)
-20 to + 55 °C (-4 to + 131 °F) -20 to + 55 °C (-4 to + 131 °F)
< 70 dB (A)
418 × 188 × 208 mm
(16.46 × 7.40 × 8.19 in.)
9.2 kg (20.28 lb)
All types intended for TIG
(GTAW) welding
5 bar (72.5 psi)
H
IP 23
- 9 -
Tig 2200i
10.7 kV
-10 to + 40 °C
(+14 to +104 °F)
< 70 dB (A)
418 × 188 × 208 mm
(16.46 × 7.40 × 8.19 in.)
418 × 188 × 345 mm
(16.46 × 7.40 × 13.58 in.)
Including cooling unit: 14 kg
(30.86 lb)
Including cooling unit, in
delivery mode: 19.4 kg (42.77
lb)
All types intended for TIG
(GTAW) welding
5 bar (72.5 psi)
H
IP 23
© ESAB AB 2019