LINKS AND CONNECTIONS
- Before proceeding with the links and connections carefully read what is presented in the PRESCRIPTIONS AND
WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION.
- All of the linking and connecting operations must be performed with the power source disconnected , if the device is not
visible a sign must be applied : " WARNING UNDER MAINTENANCE ".
1.1 Central Connections
Description ( check electical scheme , page 5)
Clamps
1
1
ANTENNA:
2
2
ANTENNA:
6
6
COMMON COMMANDS:
Imput N.C. Commands the gate's halt.
STOP:
Input
6 - 7
6 - 7
To this can be connected to safety devices such as an emergency arrest button.
Safety devices such as an emergency stop button can be connected to it.
When released the command does not do an automatic arrest , it is instead necessary to give a new
When the command is released, automatic closing is never carried out but a new movement command
movement command. Leave the bridge in place if no devices are installed.
must be given. Leave the jumper if no device is provided.
Imput N.O. Commands the opening of the gate.
6 - 8
6 - 8
OPEN:
Input
Imput N.O. Commands the gate's halt.
6 - 9
6 - 9
CLOSE :
Input
PHOTO1: With OPTION 1 Led 4, the input becomes N.C. for the connection of a photocell that intervenes
PHOTO1: With option 1 Led 4 , the imput becomes N.C. in order to connect the photocell that
in Opening and Closing.
6 - 10
6 - 10
SETP-BY-STEP:
FOUR STEPS MODE : Open,Pause,Close,Pause.
FOUR STEPS MODE: Open, Pause, Close, Pause.
SEMI-AUTOMATIC MODE: Open, Stop, Close, Stop.
SEMI-AUTOMATIC MODE : Open ,Stop,Close,Stop
CONDOMINIUM MODE: Opens (automatic closure with active pause time).
CONDOMINIUM MODE : Open (automatic closing with the active pause time).
PHOTO:
Imput N.C for photocells and safety devices . While the gate is opening doesn't intervene ,
6 - 11
6 - 11
PHOTO: N.C. input for photocells or safety devices. During the opening of the gate it does not intervene; in
PHOTO
while closing it dertermines the inversion of the motion until the complete opening.
closing it causes the inversion of the movement until the complete opening.
Leave the jumper if no device is provided.
Leave the bridge open if no devices are installed.
12 - 13
12 - 13
RELAY CONTACT
RELE' CONTACT :
RELAY CONTACT: Dry contact Relay Max 3A, default for the connection of an Open gate light. With the
activation of OPTION 2 Led 2 becomes a command for the courtesy light timed at 3 minutes.
With the activation OPTION 2 Led 2 becomes a command for the courtesy light timed at 3 minutes.
14 - 16
14 - 16
ELECTIC LOCK:
ELECTRIC LOCK: 12Vdc output for connection of 12Vdc 15VA electric lock; to activate it, select the function
ELECTRIC LOCK
from the Options menu 1 Led 3.
select the function from the Options meù n°1 Led n°3
BLINKER:
15 - 16
15 - 16
FLASHING
FLASHING: 24 Vdc 25 W max output, for connection of the flashing lamp.
16
16
+
+
EXIT 30 Vdc :
-
-
17
17
N.C. = contact normally closed - N.O = contact normally open
PEDESTRIAN:
The command determines the opening of only one side. Can be given by remote or clamps
PEDESTRIAN
PEDESTRIAN: The command causes an opening of only one leaf. It can be given by a remote control or by terminal board.
When using the terminal block a bridge will be obtained and the clamp n°8 will be OPEN , the clamp n°9 will CLOSE
This terminal is obtained by bridging terminal 8 OPEN with terminal 9 CLOSE, this jumper then connects with a switch to
this bridge will be connected to a switch at clamp n°6 common. The command PEDESTRIAN from terminl block
terminal 6 COMMON. The PEDESTRIAN command from the terminal board excludes the OPEN and CLOSE commands.
won't have the OPEN and CLOSE commands.
Connections bottom of the control unit
Input transformer power
24Vac:
24Vac:
CONN-1
CONN-1
Connection battery charger AGECH-2
CONN-2
CONN-2
Engine 2, if closed opens second.
33 - 34
33 - 34
- / +
- / +
35 - 36
35 - 36
- / +
- / +
Engine 1, if closed opens first.
4
electrical
Stocking antenna input , use RG58-50 Ohm cable.
Antenna cable imput.
input
input
For the imputs: STOP - OPEN - CLOSE - STEP BY STEP - PHOTO.
inputs
acts while in the Closing and Opening phase.
Imput N.O. Command the gate's actions following this commands :
Input N.O. Controls the movement of the gate according to the following cycles:
Clean contact Relè Max 3A , default for the connection to an open gate LED
Exit 12Vdc for the connection with the electric lock at 12Vdc 15VA; in order to activate
Exit 24 Vdc 25W max to connect the blinker
To power various devices, max 200mA.